Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
Sensor Pwr Rail A Fault has
transitioned to non-recoverable.
Error
A sensor has
changed to
Nonrecoverable
state.
1.
Turn off the server and
disconnect it from
power.
2.
Remove the optical
drive, fans, hard disk
drives, and hard disk
drive backplane.
3.
Reinstall each device,
one at a time, starting
the server each time to
isolate the failing
device.
4.
Replace the failing
device.
5.
(Trained service
technician only) Replace
the system board.
Sensor Pwr Rail B Fault has
transitioned to non-recoverable.
Error
A sensor has
changed to
Nonrecoverable
state.
1.
Turn off the server and
disconnect it from
power.
2.
Remove the optical
drive, fans, hard disk
drives, and hard disk
drive backplane.
3.
Reinstall each device,
one at a time, starting
the server each time to
isolate the failing
device.
4.
Replace the failing
device.
5.
(Trained service
technician only) Replace
the system board.
182
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...