Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
800b050a-1e83xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
Error
Cooling zone alert.
Cooling zone 3 error:
Replace fan 3.
800b050a-1e84xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
Error
Cooling zone alert.
Cooling zone 4 error:
Replace fan 4.
800b050a-1e85xxxx
Non-redundant:Insufficient Resources
for [RedundancySetElementName] has
asserted
Error
Cooling zone alert.
Cooling zone 5 error:
Replace fan 5.
806f0007-0301xxxx
806f0007-0302xxxx
The Processor CPU
n
Status has Failed
with IERR.(
n
= microprocessor
number)
Error
A processor failed -
IERR condition has
occurred.
1.
Make sure that the
latest levels of firmware
and device drivers are
installed for all adapters
and standard devices,
such as Ethernet, SCSI,
and SAS.
Important:
Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
2.
Update the firmware
(UEFI and IMM) to the
latest level “Updating
the firmware” on page
397).
3.
Run the DSA program
for the hard disk drives
and other I/O devices.
4.
Reseat the adapter.
5.
Replace the adapter.
6.
(Trained service
technician only) Replace
microprocessor
n
.
7.
(Trained service
technician only) Replace
the system board.
(
n
= microprocessor
number)
186
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...