Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
806f0021-3101xxxx
806f0021-3102xxxx
806f0021-3103xxxx
806f0021-3104xxxx
806f0021-3105xxxx
Fault in slot System board on system
%1.(%1 =
CIM_ComputerSystem.ElementName)
PCI 1
PCI 2
PCI 3
PCI 4
PCI 5
Error
1.
Check the riser-card
LEDs.
2.
Reseat the affected
adapters and riser card.
3.
Update the server
firmware (UEFI and
IMM) and adapter
firmware.
Important:
Some cluster
solutions require
specific code levels or
coordinated code
updates. If the device is
part of a cluster
solution, verify that the
latest level of code is
supported for the
cluster solution before
you update the code.
4.
Make sure that the
adapter is on the
serverproven list.
5.
Remove both adapters.
6.
Replace the PCIe
adapter.
7.
Replace the riser card.
8.
(Trained service
technician only) Replace
the system board.
806f0023-2101xxxx
Watchdog Timer expired for
[WatchdogElementName]
Info
The IPMI Watchdog
Timer has expired.
Information only; no action
is required.
806f0028-2584xxxx
Sensor [SensorElementName] is
unavailable or degraded on
management system
[ComputerSystemElementName]
Warning
PECI Bus Failure.
1.
AC power cycle system
error.
2.
Make sure that the
latest IMM, UEFI, and
FPGA firmware is
installed on the system
(see “Updating the
firmware” on page 397).
3.
(Trained service
technician only) Replace
the system board.
Chapter 3. Diagnostics
189
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...