Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
806f052b-2101xxxx
Invalid or Unsupported firmware or
software was detected on system n. (n
= system serial number).
Error
IMM firmware
failover has
occurred and IMM
has reverted to a
previous version of
the firmware.
1.
Check the IBM support
Website for an
applicable firmware
update that applies to
the server.
Attention:
Installing
the wrong firmware or
device-driver update
might cause the server
to malfunction. Before
you install a firmware
or device-driver update,
read any readme and
change history files that
are provided with the
downloaded update.
These files contain
important information
about the update and
the procedure for
installing the update,
including any special
procedure for updating
from an early firmware
or device-driver version
to the latest version.
2.
Reboot the server and
verify that the IMM is
running the correct
firmware level after the
firmware update.
806f0507-0301xxxx
806f0507-0302xxxx
The Processor CPU
n
Status has a
Configuration Mismatch.(
n
=
microprocessor number)
Error
A processor
configuration
mismatch has
occurred.
1.
Make sure that the
installed
microprocessors are
compatible with each
other (see “Replacing a
microprocessor and heat
sink” on page 351 for
information about
microprocessor
requirements).
2.
Update the server
firmware to the latest
level (see “Updating the
firmware” on page 397).
3.
(Trained service
technician only) Replace
the incompatible
microprocessor.
806f060d-0401xxxx
Array
[ComputerSystemElementName] has
failed.
Error
Array is in failed
state.
The drive array specified in
the error message (1-32) has
failed. Replace the failed
drive.
192
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...