Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
806f0123-2101xxxx
Reboot of system
[ComputerSystemElementName]
initiated by [WatchdogElementName]
Info
The IPMI Watchdog
Timer has expired.
A reboot of the
system was
initiated.
Information only; no action
is required.
806f0125-0b01xxxx
[ManagedElementName] detected as
absent
Info
The management
controller has
detected a Managed
Element is Absent.
1.
Riser card 1 is not
detected. Make sure that
it is properly seated and
connected.
2.
Replace the riser card.
806f0125-0c01xxxx
[ManagedElementName] detected as
absent
Info
The management
controller has
detected a Managed
Element is absent.
1.
Make sure that the front
panel is properly seated
and connected.
2.
Replace the front panel.
806f0125-1801xxxx
[ManagedElementName] detected as
absent.
Info
The management
controller has
detected a Managed
Element is absent.
1.
Make sure that the
memory tray is properly
seated and connected.
2.
Replace the memory
tray.
806f0125-1d01xxxx
[ManagedElementName] detected as
absent.
Info
The management
controller has
detected a Managed
Element is Absent.
1.
Fan 1 is not detected.
Make sure that it is
properly seated and
connected.
2.
Replace fan 1.
806f0125-1d02xxxx
[ManagedElementName] detected as
absent.
Info
The management
controller has
detected a Managed
Element is Absent.
1.
Fan 2 is not detected.
Make sure that it is
properly seated and
connected.
2.
Replace fan 2.
806f0125-1d03xxxx
[ManagedElementName] detected as
absent.
Info
The management
controller has
detected a Managed
Element is Absent.
1.
Fan 3 is not detected.
Make sure that it is
properly seated and
connected.
2.
Replace fan 3.
806f0125-1d04xxxx
[ManagedElementName] detected as
absent.
Info
The management
controller has
detected a Managed
Element is Absent.
1.
Fan 4 is not detected.
Make sure that it is
properly seated and
connected.
2.
Replace fan 4.
806f0125-1d05xxxx
[ManagedElementName] detected as
absent.
Info
The management
controller has
detected a Managed
Element is Absent.
1.
Fan 5 is not detected.
Make sure that it is
properly seated and
connected.
2.
Replace fan 5.
200
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...