Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
806f050c-2581xxxx
Memory Logging Limit Reached for
DIMM One of the DIMMs on Memory
Subsystem One of the DIMMs.
Error
The memory
logging limit has
been reached.
1.
Check IBM support site
for an applicable
RETAIN tip or firmware
update that applies to
this memory error.
2.
At the next maintenance
opportunity, swap the
affected DIMM (as
indicated by the light
path LED or event log
entry) to a different
memory channel. See
“Replacing a memory
module” on page 296
for information on
DIMM population
sequence.
3.
If the PFA re-occurs (on
the same DIMM),
replace the affected
DIMM as indicated by
the light path LED or
event log entry (check
for previous history of
PFA).
4.
If the problem remains
with the same DIMM
connector, inspect the
DIMM connector for
debris or damage. If the
DIMM connector is
damaged, (train
technician only) replace
the system board.
806f060d-0400xxxx
806f060d-0431xxxx
Array %1 has failed.(%1 =
CIM_ComputerSystem.ElementName)
Error
An array is in
Failed state.(Sensor
= Drive
n
Status)(
n
= hard disk drive
number)
1.
Make sure that the
RAID controller
firmware and hard disk
drive firmware is at the
latest level.
2.
Make sure that the SAS
cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the controller.
5.
Replace the hard disk
drive that is indicated
by a lit status LED.
806f070c-2581xxxx
Memory DIMM Configuration Error
for All DIMMs on Memory Subsystem
All DIMMs.
Error
A DIMM
configuration error
has occurred.
Make sure that DIMMs are
installed in the correct
sequence and have the
same size, type, speed, and
technology.
208
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...