Table 10. System x3690 X5 IMM error messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 4, “Parts listing, System x3690 X5 Types 7147, 7148, 7149, and 7192,” on page 249 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service
technician.
Event ID
Message
Severity
Description
Action
806f0a0c-2589xxxx
An Over-Temperature Condition has
been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
Error
Memory tray bank
3/4
:Over-temperature
condition.
1.
Check Retain TIPs for
known issues.
2.
Check the IMM event
log for any fan or
cooling related issues or
power related issues.
3.
Make sure that the
airflow at the front and
rear of the chassis is not
obstructed and that the
fillers are in place and
correctly installed.
4.
Make sure that the
room temperature is
within operating
specifications.
81070608-1405xxxx
Sensor VRD 3.3V has deasserted the
transition to non-recoverable
Error
A VRD error is
detected.
(Trained service technician
only) Replace the system
board.
81070608-0a01xxxx
81070608-0a02xxxx
81070608-0a03xxxx
81070608-0a04xxxx
Sensor PS
n
12V OC has deasserted
the transition to non-recoverable
Info
Power supply
n
is
normal.
No action; informational
only.
81070608-0a01xxxx
81070608-0a02xxxx
81070608-0a03xxxx
81070608-0a04xxxx
Sensor PS
n
12V OV has deasserted
the transition to non-recoverable (
n
=
power supply number)
Info
Power supply
n
is
normal.
No action; informational
only.
81070208-0a01xxxx
81070208-0a02xxxx
81070208-0a03xxxx
81070208-0a04xxxx
Sensor PS
n
Therm has transitioned to
a less severe state from critical (
n
=
power supply number)
Info
Power supply
n
is
normal.
No action; informational
only.
81070608-0a01xxxx
81070608-0a02xxxx
81070608-0a03xxxx
81070608-0a04xxxx
Sensor PS
n
VCO has deasserted the
transition to non-recoverable (
n
=
power supply number)
Info
Power supply
n
is
normal.
No action; informational
only.
81070608-0a01xxxx
81070608-0a02xxxx
81070608-0a03xxxx
81070608-0a04xxxx
Sensor PS
n
12V UV has deasserted
the transition to non-recoverable (
n
=
power supply number)
Info
Power supply
n
is
normal.
No action; informational
only.
212
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...