Table 11. IMM error messages detected when MAX5 is attached to the server (continued)
Event ID
Message
Severity
Description
Action
80010204-1d06xxxx
80010204-1d07xxxx
80010204-1d08xxxx
80010204-1d09xxxx
80010204-1d0axxxx
Numeric sensor MEU Fan
n
Tach going low (lower
critical) has asserted.(
n
= fan
number)
Error
A lower critical
sensor going low has
asserted.
1.
Reseat the failing
fan
n
, which is
indicated by a lit
LED near the fan
connector on the
MAX5 memory
expansion
module. See
“System-event
log” on page 167
and Table 9 on
page 167 for
more information
about how the
fan event
messages are
issued and the
fan number and
the device on
which the fan is
located.
2.
Replace the
failing fan.
(
n
= fan number)
80010701-1881xxxx
Numeric sensor MEU
Chipset Temp going high
(upper non-critical) has
asserted.
Info
Sensor has reported
temperature increase
from normal to
non-critical state.
Information only; no
action is required.
80010901-1881xxxx
Numeric sensor MEU
Chipset Temp going high
(upper critical) has asserted.
Warning Sensor has reported
temperature
increased from
non-critical high to a
critical high state.
1.
Make sure that
the ambient
temperature is
within the
product
specifications for
the MAX5 and
the host server.
2.
Make sure that
the fans are
operating
properly, there
are no
obstructions to
the airflow, the
air baffles are
installed correctly,
and the server
cover is installed
and completely
closed.
3.
(Trained service
technician) Make
sure that all heat
sinks are properly
installed on the
host server.
Chapter 3. Diagnostics
223
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...