Table 15. PCI slot priority sequence to install the adapter and the maximum number of
cards allowed
Name of the Adapter
Suggested slot priority
sequence in which to
install the adapter
Maximum
number of this
adapter allowed
in the server
IBM 4x4 Drive Backplane ServeRAID
Expansion adapter
Slot 1 (only)
1
Emulex 10GB Dual-port Ethernet Custom
Adapter of IBM System x
Slot 5 (only)
1
Emulex 10GbE Integrated Virtual Fabric
Adapter II for IBM System x
Slot 5 (only)
1
IBM ServeRAID M1015 SAS/SATA Controller 2, 4, 3, and then 1
2
IBM ServeRAID M5015 SAS/SATA Controller 2, 4, 3, and then 1
4
IBM ServeRAID M5016 SAS/SATA Controller 2, 4, 3, and then 1
4
IBM ServeRAID B5015 Solid State Drive
(SSD) Controller
4, 3, 1, and then 2
4
IBM 6Gb Solid State Drive (SSD) Host Bus
Adapter
4, 3, 1, and then 2
4
Note:
When you install an IBM ServeRAID M5015 SAS/SATA adapter or a
ServeRAID M5014 SAS/SATA adapter that has an M5000 battery in the server,
you must also use the ServeRAID M5000 Series Battery Remote Mount Cable
option to mount the battery remotely in the server.
v
The server provides two PCI riser-card slots on the system board. The supported
riser-cards provide up to five PCI adapter slots (depending on the riser cards
installed in the server). Some models come with PCI riser-card assemblies with
brackets installed. The following table lists the PCI slots on the supported riser
cards and the supported adapters that you can install on the riser cards:
Table 16. Supported riser cards and supported PCI adapters
Riser cards supported
Slot on the system board
to install the riser card
PCI adapters that you can install
in the riser card
PCI riser card with two
PCI Express Gen2 x8
adapter slots
PCI riser slot 1
v
PCI Express Gen2 x8
three/fourth-length, full-height
adapter
v
PCI Express Gen2 x8
half-length, full-height adapter
(Optional) PCI riser cards
with one PCI Express
Gen2 x16 adapter slot
PCI riser slot 1
v
PCI Express Gen2 x16
full-length, full-height adapter
Note:
You cannot install the
full-length, full-height adapter
in the server when the optional
memory tray is installed.
v
PCI Express Gen2 x16
three/fourth-length, full-height
adapter
PCI riser card with three
PCI Express Gen2 x8 (x4)
adapter slots
PCI riser slot 2
v
PCI Express Gen2 x8
low-profile adapter
v
PCI Express Gen2 x8 (x4)
low-profile adapter
276
System x3690 X5 Types 7147, 7148, 7149, and 7192: Problem Determination and Service Guide
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...