Performing the checkout procedure
To perform the checkout procedure, complete the following steps:
1.
Is the server part of a cluster?
v
No:
Go to step 2.
v
Yes:
Shut down all failing servers that are related to the cluster. Go to step 2.
2.
Complete the following steps:
a.
Check the power supply LEDs (see “Power-supply LEDs” on page 78).
b.
Turn off the server and all external devices.
c.
Check all internal and external devices for compatibility at
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/.
d.
Check all cables and power cords.
e.
Set all display controls to the middle positions.
f.
Turn on all external devices.
g.
Turn on the server. If the server does not start, see “Troubleshooting tables”
on page 50.
h.
Check the system-error LED on the operator information panel. If it is
flashing, check the light path diagnostics LEDs (see “Light path diagnostics”
on page 67).
Note:
When you slide the light path diagnostics panel out of the server to
check the LEDs or checkpoint codes, do not run the server continuously
with light path diagnostics panel outside of the server. The panel should
only be outside of the server a short time. The light path diagnostics panel
must remain in the server when the server is running to ensure proper
cooling.
i.
Check for the following results:
v
Successful completion of POST (see “POST” on page 38 for more
information)
v
Successful completion of startup, which is indicated by a readable display
of the operating-system desktop
3.
Is there a readable image on the monitor screen?
v
No:
Find the failure symptom in “Troubleshooting tables” on page 50; if
necessary, see “Solving undetermined problems” on page 245.
v
Yes:
Run DSA (see “Running the DSA Preboot diagnostic programs” on page
81).
– If DSA reports an error, follow the instructions in “DSA messages” on
– If DSA does not report an error but you still suspect a problem, see
“Solving undetermined problems” on page 245.
Chapter 3. Diagnostics
49
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...