To install the DIMM air baffle, complete the following steps:
1.
Read the safety information that begins on page “Safety” on page vii and
“Installation guidelines” on page 261.
2.
Align the tabs on the sides of the DIMM air baffle with the slots on the power
supply cage and the chassis wall and lower the DIMM air baffle into the server.
DIMM
air baffle
Alignment slots
RAID
battery
trays
3.
Reinstall the cover (see “Replacing the server top cover” on page 265).
4.
Slide the server into the rack.
5.
Reconnect the power cord and any cables that you removed.
6.
Turn on the peripheral devices and the server.
Attention:
For proper cooling and airflow, replace the air baffle before turning
on the server. Operating the server with an air baffle removed might damage
server components.
Removing the SAS cable guide
To remove the SAS cable guide, complete the following steps:
1.
Read the safety information and installation guidelines, see “Safety” on page vii
and “Installation guidelines” on page 261.
2.
Turn off the server (see “Turning off the server” on page 17) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
3.
Remove the top cover (see “Removing the server top cover” on page 264).
4.
Remove the fan cage assembly (see “Removing the fan cage assembly” on page
331).
5.
Disconnect and remove any SAS cables from the cable guide, then remove the
SAS cable guide.
a.
Remove the screw from the front of the cable guide (toward the front of the
server).
Chapter 5. Removing and replacing components
271
Summary of Contents for System x3690 X5
Page 1: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 8: ...vi System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 13: ...Safety statements Safety xi...
Page 22: ...4 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 266: ...248 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 278: ...260 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 386: ...368 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 407: ...1 2 Chapter 5 Removing and replacing components 389...
Page 444: ...426 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 454: ...436 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 461: ...weight of memory enclosure 28 Index 443...
Page 462: ...444 System x3690 X5 Types 7147 7148 7149 and 7192 Problem Determination and Service Guide...
Page 463: ......
Page 464: ...Part Number 47C8865 Printed in USA 1P P N 47C8865...