Superior performance/U in a 4-socket, 2U server

 

Please see the Legal Information section for important notices and information. 

DirectConnect Architecture and 

12MB

 of integrated Level 3 cache per processor offer solid 

performance capable of tackling the toughest jobs.  

  Each processor includes 

4 integrated memory controllers

 (one per memory channel), for up 

to 

16 memory controllers per server

 

Energy-efficient processors

 use less power and produce lest waste heat than less efficient 

processors, thus helping to reduce data center energy costs. For example, the 12-core 115W 
(maximum) processors 

average

 only 80W in typical use, which is under 7W per core. 

  All x3755 M3 servers support 2 DIMMs per channel (

2DPC

) at 1333MHz (using 1.5V DIMMs). 

  Fast 

PC3-10600 DDR3

 ECC memory with 

Chipkill

 error correction and 

online memory

 

sparing

 protection provides speed and high availability. 

 

Four 

high-speed 

PCIe Gen 2 

adapter slots offer investment protection by supporting high-

performance adapters, such as 10Gb Ethernet and InfiniBand cards. 

  Integrated 

ServeRAID

 controllers support 

RAID-0/1/10

 or 

RAID-0/1/10/5/50

 standard (model-

specific), upgradeable to 

RAID-0/1/10/5/50

  Up to 

eight 

3.5-inch 

hot-swap

 

SAS

 or 

SATA

 hard disk drives offer high-performance with 

high availability. 

 

Two

 integrated 

dual-port Gigabit Ethernet

 controllers with 

IPMI 2.0

 support provide 4 ports 

for high-speed network communications. 

  Support for TCP Offload Engine (

TOE

) and RDMA offers higher performance for TCP/IP 

traffic, with less overhead on the system processor.  

  A 

high degree of device integration

—including quad Gigabit Ethernet, systems 

management and video controllers—lowers costs and frees up valuable adapter slots. 

 

Flexibility 

The x3755 M3 has the ability to grow with your application requirements, thanks to:  

  A choice of Opteron processors with 

1.8 

through

 2.3GHz 

clock rates and 

79

-

137W 

maximum

 

power draw. 

  Up to 

256GB

 of high-speed DDR3 system memory (

64GB

 

per processor

). 

 

Three

 

available

 

high-performance

 adapter slots (

one PCIe x16, one x8, one x4

 in all 

models.

 

 

Hardware-based

 support for 

RAID-0/1/10

 (upgradeable to 

RAID-5/50

) is provided standard in 

most models. Other models provide 

RAID-0/1/10/5/50

 standard (upgradeable with 

RAID-6/60

 

and battery backup). 

  The 

five USB 2.0

 ports are up to 

40X

 faster

3

 than older 

USB 1.1

 ports. This provides speedy 

access to external HDDs (non-arrayed), optical drives, tape drives, and other USB devices. 
Two ports are on the front of the unit, one is internal, and two are on the back. 

  Up to 

eight

 internal 3.5-inch

 hot-swap SAS/SATA 

HDDs are supported internally (up to 

16TB 

SATA 

or

 4.8TB SAS

).

 

 

 

Manageability 

Powerful systems management features simplify local and remote management of the x3755 M3:  

  The x3755 M3 includes an integrated 

Baseboard Management Controller (iBMC)

 to monitor 

server availability, perform Predictive Failure Analysis, etc., and trigger IBM Systems Director 
alerts. The BMC enables service personnel to use sophisticated diagnostic tools, such as light 
path diagnostics and 

Serial over LAN

, to resolve problems quickly. The remote presence 

feature offers remote control of keyboard, video, and mouse, graphical console redirection 
over LAN, remote virtual floppy and CD-ROM, plus the latest OS failure screen capture. 

  Integrated 

IPMI 2.0

 support alerts IBM Systems Director to anomalous environmental factors, 

such as voltage and thermal conditions. It also supports 

highly secure remote power 

control

 using data encryption. 

 

Text Console Redirection 

support allows the administrator to remotely view x3755 M3 text 

messages over Serial or LAN. 

  Integrated industry-standard Unified Extensible Firmware Interface (

UEFI

) next-generation 

BIOS. New capabilities include:  

–  Human readable event logs — no more beep codes 

–  Complete out-of-band coverage by the Advance Settings Utility to simplify remote setup 

–  A complete setup solution, allowing adapter configuration functions to be moved into UEFI 

                                               

 

3

 Data transfer rates may be less than the maximum possible. 

Summary of Contents for System x3755 M3 7164

Page 1: ...adapter slots All models offer support for two or four processors and a choice of high performance hard disk drives with an internal storage capacity of up to 16TB eight 3 5 inch hot swap SATA drives or 4 8TB 2 four 3 5 inch hot swap SAS drives The integrated ServeRAID SAS Serial Attach SCSI SATA Serial attach ATA controller provides hardware based RAID 0 1 10 or RAID 0 1 10 5 50 support standard ...

Page 2: ...aw Up to 256GB of high speed DDR3 system memory 64GB per processor Three available high performance adapter slots one PCIe x16 one x8 one x4 in all models Hardware based support for RAID 0 1 10 upgradeable to RAID 5 50 is provided standard in most models Other models provide RAID 0 1 10 5 50 standard upgradeable with RAID 6 60 and battery backup The five USB 2 0 ports are up to 40X faster 3 than o...

Page 3: ...ut having to visit it in person saving travel time and getting the server back up and running quickly and securely It also adds new features to those provided by IPMI 1 5 including VLAN support Serial over LAN enhanced authentication and encryption algorithms RMCP and AES and a firmware firewall Temperature controlled hot swap redundant fans adjust to compensate for changing thermal characteristic...

Page 4: ... buffered memory Now a generation later DDR3 memory is even more efficient using 10 15 less energy than DDR2 memory The x3755 M3 supports up to 32 DIMMs with 8 DIMM slots assigned to each processor four memory channels with two DIMM slots and one memory controller per channel Therefore a 2 processor system is limited to 16 DIMMs Four processors are required to use all 32 DIMM slots Memory types su...

Page 5: ...s are available for added throughput and increased system availability Ultra Efficient Cooling Strategically located fans combined with efficient airflow paths provide highly effective system cooling for the x3755 M3 The server includes five hot swap fans standard These offer failover capability In addition each power supply contains a fan The system contains two cooling zones Zone 1 incorporating...

Page 6: ... operating systems to access the security features of this module TCG V1 2 compliant Five USB 2 0 ports Provides flexibility to add high speed external devices The USB 2 0 specification supports up to 480Mbps transfer rates Note Not all USB 2 0 devices are capable of achieving this rate Two ports are provided on the front of the server two are on the back and 1 is internal to support an optional f...

Page 7: ...remotely that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Text and Graphical Console Redirection support allows the administrator to remotely view system text messages and graphics over serial or LAN Predictive Failure Analysis PFA is designed to allow th...

Page 8: ...th fast 1333MHz memory access reduces memory latency and facilitates the movement of data through the processor and I O devices Note System performance depends not only on the number of processors in the server but also on the power and functionality of each processor Adding additional processors may be a cost effective way to achieve significant performance improvements Memory Memory is a signifi...

Page 9: ...rly the IBM ServeRAID M5000 Series Advance Feature Key adds RAID 6 60 support to the M5015 x3755 M3 Images Front View Rear View PCIe Slots Video Port HS Redundant Power Supplies USB Ports Serial Port 10 100 Ethernet Port for BMC Gb Ethernet Ports Hexagonal Ventilation Holes Status LEDs USB Ports 8 Hot Swap SAS SATA Bays Pop Out Light Path Diagnostics Panel Optional Optical Drive Light Path Diagnos...

Page 10: ...rage 22x 42x 62x 79W 65W average 6124HE via CTO Maximum power draw per core 14 4W 22x 42x 11 4W 6176SE 9 9W 6124HE 9 6W 62x HyperTransport link speed 3 2GHz coherent among processors 2 6GHz noncoherent between processors and I O of processors standard maximum 2 4 22x 42x 62x Internal L2 L3 processor cache 512B L2 per core 12MB L3 shared by all cores Chipset AMD SR5690 and SP5100 Standard memory5 1...

Page 11: ...ndard None of optical drives standard None of diskette drives standard None optional external USB Internal tape drives supported No Disk drive technology Hot swap SAS SATA Integrated disk controller 8 port SAS RAID of disk drives supported per port 1 External disk drives supported Yes via adapter Integrated RAID controller standard ServeRAID M1015 x8 PCIe no cache RAID 0 1 10 optional RAID 5 22x 4...

Page 12: ...Cable Management Arm provided standard Maximum altitude 7 000 ft 2 133 m Operating temperature range 50 95º F 10 35º C up to 3 000 ft 914 4 m 50 90º F 10 32º C 3 000 ft to 7 000 ft 914 4m to 2 133m Dimensions HWD weight 3 43 87mm H 17 56 446mm W 28 64 727 5mm D without front panel 29 4 747mm D with front panel 48 6 minimum 72 7 lb maximum 22 33 kg Operating systems supported Microsoft Windows Serv...

Page 13: ...t two rear one internal for a hypervisor or tape drive Optional high performance RAID controllers Four available adapter slots One x16 x16 7 PCIe Gen 2 slot 16GBps Two x8 x8 8 PCIe Gen 2 slot 8GBps One x8 x4 9 PCIe Gen 2 slots 4GBps Optional integrated optical drive Manageability Serviceability and Availability IBM Systems Director systems management software including among others IBM Systems Dir...

Page 14: ... Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2 Communities 1 2 2 2 1 1 2 3 2 2 Commerce 2 1 1 1 2 1 1 2 1 2 Collaboration 2 3 2 3 2 1 2 3 2 2 ERP SCM 1 2 1 1 1 2 1 1 1 2 CRM 2 2 2 2 2 2 2 2 1 3 Best Hosted Client 1 3 2 1 2 2 1 1 2 2 Point of Sale 3 3 3 2 1 3 1 1 1 1 Br...

Page 15: ...s or services do not imply that IBM intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this...

Reviews: