background image

Superior performance/U in a 4-socket, 2U server

 

Please see the Legal Information section for important notices and information. 

  SSL (Secure Socket Layer) and LDAP (Lightweight Directory Access Protocol) support 

  Enhanced authentication and encryption algorithms (RMCP+, AES) 

  Local update of iBMC firmware 

  Firmware firewall 

  Support for IPMI v2.0 compliant management software (e.g., xCAT) 

  Other mandatory and optional IPMI iBMC functions 

The iBMC alerts IBM Systems Director to anomalous environmental factors, such as voltage and 
thermal conditions—even if the server has failed. 

The iBMC remote presence feature offers additional systems management capabilities, including: 

  Graphical console redirection over LAN 

  Remote virtual floppy and CD-ROM 

  High-speed remote redirection of PCI video, keyboard and mouse 

IBM 

ToolsCenter

 consolidates 42 needed tools for managing servers individually into an 

integrated suite of 8 tools. They are organized by function: deployment, updates, configuration 
and diagnostics. Tools are now simpler to access and use with a single webpage for access, a 
common look and feel and a common command line interface for the scripting tools. The 
ToolsCenter 

Bootable Media Creator 

offers significantly more functionality than past tools with 

the ability to add more tools to the bootable image and to automatically download the bootable 
environment if needed. Bootable Media Creator allows you to create bootable CDs, DVD, and 
USB keys for updates customized to your systems. 

Automatic Server Restart

 (ASR) helps reduce downtime by restarting the server automatically 

in the event of a system lockup. If the operating system crashes or the hardware freezes, it 
automatically triggers the ASR hardware, which immediately restarts the server (and logs an ASR 
event with IBM Systems Director). These features are designed so that 

no more than five minutes 

can pass before the server is restarted

Wake on LAN

 permits the server to be remotely powered on if it has been shut off. Once 

powered up, the server can be controlled across the network, using the 

Preboot Execution 

Environment

 (PXE). 

Like Wake on LAN, PXE is system firmware. It enables software to take control of a system 
before the BIOS, operating system or applications are loaded (using Wake on LAN/PXE) and lets 
an administrator perform many low-level tasks remotely that would otherwise require a visit to 
each system. These tasks may include such things as formatting a hard disk drive, updating 
system firmware, or deploying a Windows or Linux operating system.  

Text and Graphical Console Redirection 

support allows the administrator to remotely view 

system text messages and graphics over serial or LAN. 

Predictive Failure Analysis

 

(PFA)

 is designed to allow the x3755 M3 to detect impending failure 

of supported components (processors, memory, power supplies, fans, and hard disk drives) 

before

 actual failure, and alert the administrator through IBM Systems Director. This gives you 

the ability to replace the failing component 

before

 it fails, resulting in increased uptime. 

IBM Systems

 

Director 

software for advanced workgroup management is included standard. IBM 

Systems Director comes with a portfolio of tools. 

System Availability

 (a no-charge download) and 

Capacity Manager 

(sold separately) are available as add-ons for additional server management 

and increased availability. IBM Systems Director provides a single uniform graphical interface for 
all of these systems management functions. IBM Systems Director enables you to customize 
thresholds and monitor system components (for things like temperature, voltage regulation, etc.) 
to help maximize uptime.

 

 

Extensive System Support Features 

The IBM services and technical support portfolio provides world-class, consistent, high-quality 
service and support. The x3755 M3 offers a number of tools and services designed to make 
ownership a positive experience. From the start, IBM programs make it easier for you to plan for, 
configure and purchase System servers, get them running and keep them running long-term. 
These features include IBM ServerProven, the IBM Standalone Solutions Configuration Tool, 
IIBM ServerGuide, Product Customization Services and extensive technical support offerings. 

The IBM 

ServerProven

 program provides the confidence that specific options and operating 

systems have been tested on the server and are officially supported to work together. It is 
updated frequently to ensure that the latest compatibility information is always at your fingertips. 

The IBM 

Standalone Solutions Configuration Tool 

(SSCT) is a downloadable tool that 

simplifies the often complex chore of configuring a full rack of servers (including blade servers) 
and confirming that you have all the cables, power distribution units, KVM (keyboard, video and 
mouse) switch boxes and other components you need, as well as the proper airflow clearances, 

Summary of Contents for System x3755 M3 7164

Page 1: ...adapter slots All models offer support for two or four processors and a choice of high performance hard disk drives with an internal storage capacity of up to 16TB eight 3 5 inch hot swap SATA drives or 4 8TB 2 four 3 5 inch hot swap SAS drives The integrated ServeRAID SAS Serial Attach SCSI SATA Serial attach ATA controller provides hardware based RAID 0 1 10 or RAID 0 1 10 5 50 support standard ...

Page 2: ...aw Up to 256GB of high speed DDR3 system memory 64GB per processor Three available high performance adapter slots one PCIe x16 one x8 one x4 in all models Hardware based support for RAID 0 1 10 upgradeable to RAID 5 50 is provided standard in most models Other models provide RAID 0 1 10 5 50 standard upgradeable with RAID 6 60 and battery backup The five USB 2 0 ports are up to 40X faster 3 than o...

Page 3: ...ut having to visit it in person saving travel time and getting the server back up and running quickly and securely It also adds new features to those provided by IPMI 1 5 including VLAN support Serial over LAN enhanced authentication and encryption algorithms RMCP and AES and a firmware firewall Temperature controlled hot swap redundant fans adjust to compensate for changing thermal characteristic...

Page 4: ... buffered memory Now a generation later DDR3 memory is even more efficient using 10 15 less energy than DDR2 memory The x3755 M3 supports up to 32 DIMMs with 8 DIMM slots assigned to each processor four memory channels with two DIMM slots and one memory controller per channel Therefore a 2 processor system is limited to 16 DIMMs Four processors are required to use all 32 DIMM slots Memory types su...

Page 5: ...s are available for added throughput and increased system availability Ultra Efficient Cooling Strategically located fans combined with efficient airflow paths provide highly effective system cooling for the x3755 M3 The server includes five hot swap fans standard These offer failover capability In addition each power supply contains a fan The system contains two cooling zones Zone 1 incorporating...

Page 6: ... operating systems to access the security features of this module TCG V1 2 compliant Five USB 2 0 ports Provides flexibility to add high speed external devices The USB 2 0 specification supports up to 480Mbps transfer rates Note Not all USB 2 0 devices are capable of achieving this rate Two ports are provided on the front of the server two are on the back and 1 is internal to support an optional f...

Page 7: ...remotely that would otherwise require a visit to each system These tasks may include such things as formatting a hard disk drive updating system firmware or deploying a Windows or Linux operating system Text and Graphical Console Redirection support allows the administrator to remotely view system text messages and graphics over serial or LAN Predictive Failure Analysis PFA is designed to allow th...

Page 8: ...th fast 1333MHz memory access reduces memory latency and facilitates the movement of data through the processor and I O devices Note System performance depends not only on the number of processors in the server but also on the power and functionality of each processor Adding additional processors may be a cost effective way to achieve significant performance improvements Memory Memory is a signifi...

Page 9: ...rly the IBM ServeRAID M5000 Series Advance Feature Key adds RAID 6 60 support to the M5015 x3755 M3 Images Front View Rear View PCIe Slots Video Port HS Redundant Power Supplies USB Ports Serial Port 10 100 Ethernet Port for BMC Gb Ethernet Ports Hexagonal Ventilation Holes Status LEDs USB Ports 8 Hot Swap SAS SATA Bays Pop Out Light Path Diagnostics Panel Optional Optical Drive Light Path Diagnos...

Page 10: ...rage 22x 42x 62x 79W 65W average 6124HE via CTO Maximum power draw per core 14 4W 22x 42x 11 4W 6176SE 9 9W 6124HE 9 6W 62x HyperTransport link speed 3 2GHz coherent among processors 2 6GHz noncoherent between processors and I O of processors standard maximum 2 4 22x 42x 62x Internal L2 L3 processor cache 512B L2 per core 12MB L3 shared by all cores Chipset AMD SR5690 and SP5100 Standard memory5 1...

Page 11: ...ndard None of optical drives standard None of diskette drives standard None optional external USB Internal tape drives supported No Disk drive technology Hot swap SAS SATA Integrated disk controller 8 port SAS RAID of disk drives supported per port 1 External disk drives supported Yes via adapter Integrated RAID controller standard ServeRAID M1015 x8 PCIe no cache RAID 0 1 10 optional RAID 5 22x 4...

Page 12: ...Cable Management Arm provided standard Maximum altitude 7 000 ft 2 133 m Operating temperature range 50 95º F 10 35º C up to 3 000 ft 914 4 m 50 90º F 10 32º C 3 000 ft to 7 000 ft 914 4m to 2 133m Dimensions HWD weight 3 43 87mm H 17 56 446mm W 28 64 727 5mm D without front panel 29 4 747mm D with front panel 48 6 minimum 72 7 lb maximum 22 33 kg Operating systems supported Microsoft Windows Serv...

Page 13: ...t two rear one internal for a hypervisor or tape drive Optional high performance RAID controllers Four available adapter slots One x16 x16 7 PCIe Gen 2 slot 16GBps Two x8 x8 8 PCIe Gen 2 slot 8GBps One x8 x4 9 PCIe Gen 2 slots 4GBps Optional integrated optical drive Manageability Serviceability and Availability IBM Systems Director systems management software including among others IBM Systems Dir...

Page 14: ... Modeling Simulation 2 1 1 1 3 1 3 2 3 3 High Performance DB 2 2 1 1 1 3 2 2 3 3 Business Intelligence 2 1 1 1 2 1 2 2 1 3 Search 3 1 1 1 2 1 3 3 1 2 Content 2 2 2 2 2 1 3 3 2 2 Communities 1 2 2 2 1 1 2 3 2 2 Commerce 2 1 1 1 2 1 1 2 1 2 Collaboration 2 3 2 3 2 1 2 3 2 2 ERP SCM 1 2 1 1 1 2 1 1 1 2 CRM 2 2 2 2 2 2 2 2 1 3 Best Hosted Client 1 3 2 1 2 2 1 1 2 2 Point of Sale 3 3 3 2 1 3 1 1 1 1 Br...

Page 15: ...s or services do not imply that IBM intends to make them available in all countries in which IBM operates IBM PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions therefore this...

Reviews: