Error
message
Action
PCI-PCI
bridge
secondary:
Slave
signaled
parity
error.
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI-PCI
bridge
secondary:
Signaled
target
abort
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI-PCI
bridge
secondary:
Additional
correctable
ECC
error
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
Informational
only;
if
the
message
remains:
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI-PCI
bridge
secondary:
Received
master
abort
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI-PCI
bridge
secondary:
Additional
uncorrectable
ECC
error
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI-PCI
bridge
secondary:
Split
completion
discarded
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.
PCI-PCI
bridge
secondary:
Correctable
ECC
error
Chassis#=X
Slot#=Y
Bus#=Z
Dev.ID=0xSSSS
Vend.ID=0xTTTT
Status=0xUUUU
DevFun#=0xVV
Informational
only;
if
the
message
remains:
1.
If
the
slot
number
is
greater
than
0,
complete
the
following
steps:
a.
Reseat
the
adapter.
b.
Replace
the
adapter.
2.
If
the
slot
number
is
0,
replace
the
PCI
board.