Specifications
This section lists the physical specifications for your computer.
Dimensions
Height: 104 mm (4.1 in.)
Width: 360 mm (14.2 in.)
Depth: 412 mm (16.2 in.)
Weight
Minimum configuration as shipped: 8.1 kg (18 lb)
Maximum configuration: 9.1 kg (20 lb)
Environment
Air temperature:
System on: 10° to 35°C (50° to 95° F)
System off: 10° to 43°C (50° to 110° F)
Maximum altitude: 2134 m (7000 ft)
Note:
The maximum altitude, 2134 m (7000 ft),
is the maximum altitude at which the specified
air temperatures apply. At higher altitudes, the
maximum air temperatures are lower than those
specified.
Humidity:
System on: 8% to 80%
System off: 8% to 80%
Electrical input
Input voltage:
Low range:
Minimum: 90 V ac
Maximum: 180 V ac
Input frequency range: 47–53 Hz
Voltage switch setting: 115 V ac
High range:
Minimum: 137 V ac
Maximum: 265 V ac
Input frequency range: 57–63 Hz
Voltage switch setting: 230 V ac
Input kilovolt-amperes (kVA) (approximate):
Minimum configuration as shipped: 0.08 kVA
Maximum configuration: 0.25 kVA
Note:
Power consumption and heat output vary
depending on the number and type of optional
features installed and the power-management
optional features in use.
Heat output
(approximate) in British thermal units (Btu)
per hour:
Minimum configuration: 257 Btu/hr (75 watts)
Maximum configuration: 683 Btu/hr (200 watts)
Airflow
Approximately 0.45 cubic meters per minute (16 cubic
feet per minute) maximum
Acoustical noise-emission values
For microprocessors less than 2.8 GHz:
Average sound-pressure levels:
At operator position:
Idle: 28 dBA
Operating: 30 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 27 dBA
Operating: 29 dBA
Declared (upper limit) sound-power levels:
Idle: 4.2 bels
Operating: 4.3 bels
For microprocessors greater than or equal to 2.8 GHz:
Average sound-pressure levels:
At operator position:
Idle: 29 dBA
Operating: 31 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 28 dBA
Operating: 29 dBA
Declared (upper limit) sound-power levels:
Idle: 4.3 bels
Operating: 4.4 bels
Note:
These levels were measured in controlled acoustical
environments according to the procedures specified by the
American National Standards Institute (ANSI) S12.10 and
ISO 7779 and are reported in accordance with ISO 9296.
Actual sound-pressure levels in a given location might
exceed the average values stated because of room
reflections and other nearby noise sources. The declared
sound-power levels indicate an upper limit, below which a
large number of computers will operate.
4
User Guide
Summary of Contents for ThinkCentre A30 8198
Page 1: ...ThinkCentre User Guide Types 2296 8191 8198 8199 8316 8434...
Page 2: ......
Page 3: ...ThinkCentre User Guide Types 2296 8191 8198 8199 8316 8434...
Page 34: ...22 User Guide...
Page 108: ...96 User Guide...
Page 120: ...108 User Guide...
Page 122: ...110 User Guide...
Page 127: ......
Page 128: ...Part Number 74P2399 Printed in U S A 1P P N 74P2399...