Function-Related Symptoms
Symptom / Error
FRU / Action in Sequence
The system does not
suspend or resume when
the LCD is closed or
opened.
1. Go to “Suspend
Mode” on page 35,
and check that the
computer can enter
suspend mode.
2. Boot an operating
system and press
Fn
+
F4. If the
computer enters
suspend mode,
suspect that the
application program is
not working properly.
3. LCD assembly
4. System board
The battery Fuel-Gauge
does not go higher than
90%.
Go to “Battery Checkout”
on page 30 and see the
note.
The memory count (size)
appears different from the
actual size.
Go to “Memory Checkout”
on page 28.
The system configuration
does not match the installed
devices.
Go to “Checking the
Installed Devices List” on
page 50.
The system hangs
intermittently.
Go to “Intermittent
Problems” on page 47.
Indicator-Related Symptoms
Symptom / Error
FRU / Action in Sequence
The indicator incorrectly
remains off or on, but the
system runs correctly.
1. System board
2. DC/DC card
The battery power status
indicator blinks from green,
yellow, to orange.
1. Check that a correct
battery is installed.
2. Battery pack
3. DC/DC card
4. System board
The battery indicator does
not turn on when the battery
is installed.
1. DC/DC card
2. Battery pack
3. System board
44
IBM ThinkPad 380XD, 385XD
Summary of Contents for ThinkPad 380XD
Page 2: ......
Page 8: ...vi IBM ThinkPad 380XD 385XD ...
Page 88: ...2635 8xx 9xx Axx Bxx 2635 Dxx Exx Fxx 80 IBM ThinkPad 380XD 385XD ...
Page 110: ...When replacing Replace the LCD miscellaneous parts as follows 102 IBM ThinkPad 380XD 385XD ...
Page 111: ...2050 LCD Cable IBM ThinkPad 380XD 385XD 2635 103 ...
Page 119: ...LCD FRU HPA Labeled 05K9309 or 05K9320 IBM ThinkPad 380XD 385XD 2635 111 ...
Page 121: ...TFT 1 Labeled 05K9312 or 05K9322 IBM ThinkPad 380XD 385XD 2635 113 ...
Page 123: ...TFT 2 Labeled 05K9311 or 05K9321 IBM ThinkPad 380XD 385XD 2635 115 ...
Page 132: ...IBM Part Number 10L9623 Printed in U S A S1ðL 9623 ðð ...