8. Click on a device to test, or click on Test All to test
all devices.
Click on Looptest to run the tests in a repeated loop.
The loop option menu appears. Click on a device; a
√
mark appears beside the selected device. Repeat
this step to select multiple devices. Click on OK to
start the diagnostic loop. If no device is selected, all
devices tests are looped.
9. To exit the loop, keep pressing Ctrl
+
Pause. A beep
sounds to notify that exit interrupt is sensed by the
test program. Press Esc to exit from the loop test.
PC Card (PCMCIA) Slots Test
The green LED on the PC test card (P/N 35G4703) turns
on when the PC Card (PCMCIA) slot test is running. If the
LED does not turn on, check that the card is installed
correctly by reseating it. If the LED still does not turn on
after the card is reseated, try using another slot for the
test. If the LED still does not turn on and the test fails,
replace the FRU shown by the diagnostic error code.
Universal Serial Bus (USB) Test
At the advanced diagnostic test menu, connect the USB
parallel test cable (P/N 05K2580) to the computer. Click
on the USB icon to run the test. Follow the instructions on
the screen. OK appears if the test passes and three lines
of error codes appear if the test fails. The defective FRU
must be the DC/DC card or the system board.
Use cable number 2 for an external USB port on the port
replicator.
Displaying the Error Log
Diagnostic errors are printed on a printer that is attached
to the parallel port when the error is detected. The error is
also logged in the system memory.
Use the following procedures to display the errors:
1. Enter the advanced diagnostic test.
2. Press Ctrl
+
E.
3. The error log appears.
4. To exit the window, click on Exit or press Esc key.
The error log is not saved when the system power is
turned off.
Checking the Installed Devices List
If a device is installed but its icon appears in gray shade
rather than in dark shade on the basic diagnostics test
menu, the device is defective. Reseat the device
connectors. If the symptom remains, replace the device or
the system board. If needed, adjust the contrast control to
clearly distinguish the shades of the icon.
50
IBM ThinkPad 380XD, 385XD
Summary of Contents for ThinkPad 380XD
Page 2: ......
Page 8: ...vi IBM ThinkPad 380XD 385XD ...
Page 88: ...2635 8xx 9xx Axx Bxx 2635 Dxx Exx Fxx 80 IBM ThinkPad 380XD 385XD ...
Page 110: ...When replacing Replace the LCD miscellaneous parts as follows 102 IBM ThinkPad 380XD 385XD ...
Page 111: ...2050 LCD Cable IBM ThinkPad 380XD 385XD 2635 103 ...
Page 119: ...LCD FRU HPA Labeled 05K9309 or 05K9320 IBM ThinkPad 380XD 385XD 2635 111 ...
Page 121: ...TFT 1 Labeled 05K9312 or 05K9322 IBM ThinkPad 380XD 385XD 2635 113 ...
Page 123: ...TFT 2 Labeled 05K9311 or 05K9321 IBM ThinkPad 380XD 385XD 2635 115 ...
Page 132: ...IBM Part Number 10L9623 Printed in U S A S1ðL 9623 ðð ...