Function-Related Symptoms
Symptom / Error
FRU / Action in Sequence
The system does not
suspend or resume when
the LCD is closed or
opened.
1. Go to “Suspend
Mode” on page 34,
and check that the
computer can enter
suspend mode.
2. Boot an operating
system and press
Fn
+
F4. If the
computer enters
suspend mode,
suspect that the
application program is
not working properly.
3. LCD assembly.
4. System board.
The battery Fuel-Gauge
does not go higher than
90%.
Go to “Checking the
Battery Pack” on page 31
and see the note.
The memory count (size)
appears different from
actual size.
Go to “Memory Checkout”
on page 28.
The system configuration
does not match the installed
devices.
Go to “Checking the
Installed Devices List” on
page 49.
The system hangs
intermittently.
Go to “Intermittent
Problems” on page 45.
Indicator-Related Symptoms
Symptom / Error
FRU / Action in Sequence
The indicator incorrectly
remains off or on, but
system runs correctly.
System board.
DC/DC card.
The battery power status
indicator blinks from green,
yellow, to orange.
1. Check that a correct
battery is installed.
2. Battery pack.
3. DC/DC card.
4. System board.
The battery indicator does
not turn on when the battery
is installed.
DC/DC card.
Battery pack.
System board.
42
IBM ThinkPad 560X (2640-60x, 70x) HMM
Summary of Contents for ThinkPad 560X
Page 2: ......
Page 8: ...vi IBM ThinkPad 560X 2640 60x 70x HMM...
Page 10: ...viii IBM ThinkPad 560X 2640 60x 70x HMM...
Page 28: ...18 IBM ThinkPad 560X 2640 60x 70x HMM...
Page 72: ...1030 Battery Pack Turn the computer upside down 62 IBM ThinkPad 560X 2640 60x 70x HMM...
Page 74: ...64 IBM ThinkPad 560X 2640 60x 70x HMM...
Page 92: ...82 IBM ThinkPad 560X 2640 60x 70x HMM...
Page 94: ...84 IBM ThinkPad 560X 2640 60x 70x HMM...
Page 98: ...Parts Listing 560X 2640 60x 70x 88 IBM ThinkPad 560X 2640 60x 70x HMM...
Page 110: ...IBM Part Number 05L1768 Printed in U S A S 5L 1768...