3.
With
the
SFP
latch
in
the
unlocked
position,
slide
the
SFP
module
out
of
the
port.
4.
Replace
the
protective
cap
on
the
SFP
module.
5.
Place
the
SFP
module
into
a
static-protective
package.
Handling
fiber-optic
cables
Before
using
fiber-optic
cables,
read
the
following
precautions.
Attention:
To
avoid
damage
to
your
fiber-optic
cables,
follow
these
guidelines:
v
Do
not
route
the
cable
along
a
folding
cable-management
arm.
v
When
connecting
cables
to
a
device
on
slide
rails,
leave
enough
slack
in
the
cable
so
that
it
does
not
bend
to
a
radius
of
less
than
38
mm
(1.5
in.)
when
extended
or
become
pinched
when
retracted.
v
Route
the
cable
away
from
places
where
it
can
be
snagged
by
other
devices
in
the
rack.
v
Do
not
overtighten
the
cable
straps
or
bend
the
cables
to
a
radius
of
less
than
38
mm
(1.5
in.).
v
Do
not
put
excess
weight
on
the
cable
at
the
connection
point.
Be
sure
that
the
cable
is
well
supported.
Using
LC-LC
fibre
channel
cables
The
LC-LC
fibre
channel
cable,
shown
in
is
a
fiber-optic
cable
that
is
used
to
connect
into
one
of
the
following
devices:
v
SFP
module
installed
in
a
storage
expansion
enclosure
v
SFP
module
installed
in
a
DS4000
storage
server
For
more
information
about
cabling
these
devices,
see
the
documentation
that
comes
with
the
LC-LC
fibre
channel
cable.
o
Protective
cap
Wire
tab
SFP
module
90
Figure
24.
Unlocking
the
SFP
module
latch
-
wire
variety
Chapter
2.
Installing
and
cabling
the
storage
expansion
enclosure
35