5. Connect port 1B on the right ESM of the ninth EXP5000 (9) to port 1 of drive
channel 5 on the DS5100 and DS5300.
6. Distribute the remainder of the EXP5000s equally across the drive ports as
appropriate and connect the cables using a similar process described in this
section.
The end result is two EXP5000 storage expansion enclosures per port for a
total of 16 storage expansion enclosures.
One DS5100 and DS5300 and one EXP5060 storage expansion
enclosure
Table 23. Cabling for DS5100 and DS5300 storage subsystem with one EXP5060 storage expansion enclosure
without trunking
Cable
Controller A Connection
Controller B Connection
Storage Expansion Enclosure
Connection
Ch1
Ch2
Ch3
Ch4
Ch5
Ch6
Ch7
Ch8
ESM A (Top)
ESM B (Bottom)
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
1A
1B
2A
2B
1A
1B
2A
2B
Storage Expansion Enclosure 1
1
X
X
2
X
X
One DS5100 and DS5300 and two EXP5060 storage expansion
enclosures
1A 1B
A
B
1A 1B
8
6
5
7
4
2
1
3
1
B
A
8
6
5
7
4
2
1
3
Figure 56. Cabling for DS5100 and DS5300 storage subsystem with one EXP5060 storage
expansion enclosure without trunking
Chapter 3. Cabling the storage subsystem
85