Note:
Correct
any
faults
before
you
turn
off
the
power
to
the
storage
subsystem
using
the
proper
troubleshooting
or
servicing
procedures.
This
will
help
ensure
that
the
storage
expansion
enclosures
will
operate
correctly
after
the
upgrade.
6.
Stop
the
applications
in
the
server
and
then
power
down
your
storage
subsystem.
Note:
Power
down
the
DS4000
storage
server
first
and
then
power
down
the
storage
expansion
enclosures.
For
more
information,
see
the
Installation,
User’s,
and
Maintenance
Guide
for
your
DS4000
storage
server.
7.
Whether
you
are
upgrading
one
or
multiple
DS4000
EXP700s
in
a
drive
loop,
complete
the
disconnection,
upgrade,
and
reconnection
process
described
in
the
following
steps
for
each
storage
expansion
enclosure
before
upgrading
the
next
storage
expansion
enclosure.
Disconnecting,
upgrading,
and
reconnecting
one
DS4000
EXP700
at
time
greatly
reduces
the
possibility
of
making
a
fibre
channel
cabling
error.
Note:
Before
upgrading
the
ESMs,
review
the
guidelines
in
a.
Disconnect
all
fibre
channel
cables
from
the
left
ESM
in
the
first
storage
expansion
enclosure
that
you
will
upgrade.
b.
Replace
the
left
ESM
with
the
upgrade
ESM
CRU
that
you
received
in
the
DS4000
EXP700
Models
1RU/1RX
Switched-ESM
Option
Upgrade
Kit.
Follow
the
steps
for
replacing
an
ESM
in
c.
Reconnect
the
fibre
channel
cables
to
the
upgraded
ESM
in
the
first
storage
expansion
enclosure.
d.
Repeat
steps
a
through
c
for
the
right
ESM
in
the
first
storage
expansion
enclosure
that
you
will
upgrade.
e.
Replace
the
DS4000
EXP700
bezel
with
the
new
bezel
you
received
in
the
DS4000
EXP700
Models
1RU/1RX
Switched-ESM
Option
Upgrade
Kit.
f.
Repeat
steps
a
through
e
for
each
DS4000
EXP700
that
you
are
upgrading.
Complete
the
process
for
each
DS4000
EXP700
before
you
continue
with
the
next
storage
expansion
enclosure.
8.
Power
on
your
storage
subsystem.
Use
the
LEDs
to
verify
that
the
DS4000
configuration
is
operating
normally.
Correct
any
Fault
LED
errors
and
verify
that
the
ESM
port
bypass
LEDs
are
not
lit
(if
they
are,
remove
the
fibre
channel
cables
and
the
SFPs
and
reinsert
them).
Note:
Power
up
the
storage
expansion
enclosures
first
and
then
power
up
the
DS4000
storage
server.
For
more
information,
see
the
Installation,
User’s,
and
Maintenance
Guide
for
your
DS4000
storage
server.
9.
Use
the
Storage
Manager
client
Subsystem
Management
window
to
verify
that
the
DS4000
storage
server
configuration
is
in
an
optimal
state
and
that
no
ESM
Redundancy
Lost
errors
or
drive
errors
are
being
reported.
Use
the
Recovery
Guru
function
in
the
Storage
Manager
client
Subsystem
Management
window
for
information
on
how
to
fix
any
non-optimal
conditions.
If
you
experience
any
of
the
following
drive
failure
conditions,
call
IBM
support
for
help:
v
The
Empty
Drive
Slot
icon
(
)
displayed
for
drive
slots
that
contain
drives.
Appendix
B.
Upgrading
ESMs
with
the
DS4000
EXP700
Models
1RU/1RX
Switched-ESM
Option
Upgrade
Kit
87
Summary of Contents for TotalStorage FAStT EXP700
Page 2: ......
Page 157: ......
Page 158: ...Part Number 25R0398 Printed in USA gc26 7735 00 1P P N 25R0398...