Table 32. Voltage-related shutdown (continued)
Message
Action
System shutoff due to
x
V under voltage
(level-critical system shutoff due to
x
supply
under voltage)
1. Check the power-supply connectors.
2. Power supply.
3. Power cage assembly.
System shutoff due to VRM x over
voltage
Replace VRM
x
.
System shutoff due to excessive (< 240
VA) loading
1. See “Power checkout” on page 105.
2. Cycle ac on/off.
Temperature-related appliance engine shutdown
Table 33. Temperature related shutdown
Message
Action
System shutoff due to board over
temperature
(level-critical; board is over
temperature)
1. Ensure that the system is being correctly cooled; refer to
“Specifications” in Chapter 1 of the hardware installation guide.
2. Replace board.
System shutoff due to CPU x over
temperature
(level-critical; CPU
x
is over
temperature)
1. Ensure that the system is being correctly cooled; refer to
“Specifications” in Chapter 1 of the hardware installation guide.
2. Replace CPU
x
.
System shutoff due to CPU
x
under
temperature
(level-critical; CPU
x
is under
temperature)
Ambient temperature must be within normal operating specifications;
refer to “Specifications” in Chapter 1 of the hardware installation
guide.
System shutoff due to DASD temperature
(sensor
x
)
(level-critical; DASD area
reported temperature outside recommended
operating range)
Ensure that the system is being correctly cooled; refer to
“Specifications” in Chapter 1 of the hardware installation guide.
System shutoff due to high ambient
temperature
(level-critical; high ambient
temperature)
Ambient temperature must be within normal operating specifications;
refer to “Specifications” in Chapter 1 of the hardware installation
guide.
System shutoff due to system board
under temperature
(level-critical; system
board is under temperature)
Ambient temperature must be within normal operating specifications;
refer to “Specifications” in Chapter 1 of the hardware installation
guide.
Temperature error messages
Table 34. Temperature error messages
Message
Action
DASD Over Temperature
(level-critical;
direct access storage device bay
x
was
over temperature)
Ensure that the system is being correctly cooled; refer to
“Specifications” in Chapter 1 of the hardware installation guide.
DASD Over recommended Temperature
(sensor
x
)
(level-warning; DASD bay
x
had
over temperature condition)
Ensure that the system is being correctly cooled; refer to
“Specifications” in Chapter 1 of the hardware installation guide.
DASD under recommended temperature
(sensor
x
)
(level-warning; direct access
storage device bay
x
had under
temperature condition)
Ambient temperature must be within normal operating specifications;
refer to “Specifications” in Chapter 1 of the hardware installation guide.
150
NAS Gateway 300 User’s Reference
Summary of Contents for TotalStorage NAS 300
Page 1: ...TotalStorage NAS Gateway 300 Model G27 User s Reference GA27 4321 00...
Page 8: ...viii NAS Gateway 300 User s Reference...
Page 10: ...x NAS Gateway 300 User s Reference...
Page 14: ...xiv NAS Gateway 300 User s Reference...
Page 26: ...12 NAS Gateway 300 User s Reference...
Page 40: ...26 NAS Gateway 300 User s Reference...
Page 46: ...32 NAS Gateway 300 User s Reference...
Page 68: ...54 NAS Gateway 300 User s Reference...
Page 134: ...120 NAS Gateway 300 User s Reference...
Page 136: ...122 NAS Gateway 300 User s Reference...
Page 168: ...154 NAS Gateway 300 User s Reference...
Page 182: ...168 NAS Gateway 300 User s Reference...
Page 199: ......
Page 200: ...Printed in U S A GA27 4321 00...