Step 1548-7
No failure was detected with this configuration.
1. Turn off the power and remove the power cords.
2. Reinstall processor card #2.
3. Plug in the power cords and wait for the operator panel to display
OK
.
4. Turn on the power.
Does the system stop with code E1F2, E1F3, STBY or 20EE000B, 4BA00830 displayed on the
operator panel?
NO
One of the FRUs remaining in the system unit is defective.
Exchange the FRUs that have not been exchanged, in the following order:
1. DIMMs, if present on processor card #2, exchange one at a time with new or previously
removed DIMMs.
2. Processor card #2 (last one installed).
3. CEC backplane.
Repeat this step until the defective FRU is identified or all the FRUs have been exchanged.
If the symptom did not change and all the FRUs have been exchanged, call your service support
person for assistance.
If the symptom changed, check for loose cards and obvious problems. If you do not find a
problem, go to the “Quick Entry MAP” on page 40 and follow the instructions for the new symptom.
YES
Go to “Step 1548-8”.
Step 1548-8
1. Turn off the power.
2. Reconnect the system console.
Note:
If an ASCII terminal has been defined as the system console, attach the ASCII terminal cable to
the S1 connector on the back of the system unit.
3. Turn on the power.
4. If the ASCII terminal is connected differently than it was before, the Console Selection panel appears
and requires that a new console be selected.
5. When the word
keyboard
is displayed, press 1 on the ASCII terminal. This activates the System
Management Services (SMS).
6. If you are prompted to do so, enter the appropriate password.
Is the SMS panel displayed?
NO
One of the FRUs remaining in the system unit is defective.
Exchange the FRUs that have not been exchanged.
Repeat this step until the defective FRU is identified or all the FRUs have been exchanged.
If the symptom did not change and all the FRUs have been exchanged, call service support for
assistance.
If the symptom changed, check for loose cards, cables, and obvious problems. If you do not find a
problem, go to the “Quick Entry MAP” on page 40 and follow the instructions for the new symptom.
YES
Go to “Step 1548-9” on page 82.
Chapter 3. Maintenance Analysis Procedures (MAPs)
81
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...