Table 10. Firmware checkpoints (continued)
Checkpoint
Description
Action or
possible failing FRU
E1FB
Scan SCSI bus for attached devices
1. If a location code is available, follow the
repair actions listed for firmware error
code 21A0 00XX.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 69.
E1FD
The operator panel alternates between the
code E1FD and another Exxx code, where
Exxx is the point at which the error
occurred.
1. If a location code is available, follow the
actions listed for firmware error code
21A0 00xx.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 69.
E1FE
Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
1. If a location code is available, follow the
repair actions listed for error code
firmware 21A0 00XX.
2. If no location code is available, go to
“MAP 1540: Problem Isolation
Procedures” on page 69.
E1FF
Building boot device list for fibre-channel
adapters. (The WWPN of the SAN adapter
being scanned is also displayed.)
Go to “MAP 1542: I/O Problem Isolation” on
page 72.
E20F
System firmware has exited to open
firmware prompt
1. Replace the CEC backplane,
Location: U0.1-P1.
2. Call service support.
E440
Validate NVRAM, initialize partitions as
needed
1. Check for system firmware updates.
2. Replace the CEC backplane,
Location: U0.1-P1.
3. Call service support.
E441
Generate /options node NVRAM
configuration variable properties
1. Check for system firmware updates.
2. Replace the CEC backplane,
Location: U0.1-P1.
3. Call service support.
E442
Validate NVRAM partitions
1. Check for system firmware updates.
2. Replace the CEC backplane,
Location: U0.1-P1.
3. Call service support.
E443
Generate NVRAM configuration variable
dictionary words
Suspect a system firmware problem if
problem persists. If a system firmware
update is available, install it. If not, call
service support.
E500
Begin I/O drawer configuration
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
E501
Initialize I/O data structures
1. Check for system firmware updates.
2. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
106
NAS Gateway 500 Service Guide
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...