Table 14. SPCN error codes for I/O subsystems (continued)
Error code Description
Action or
possible failing FRU
1nn1 1517 Power supply 1 thermal fault
1. Check for obstructions to the air flow around
the I/O subsystem.
2. I/O subsystem power supply 1, U0.dd-V1.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1520 Power supply 2 source failure
1. Check the input voltage to the power supply.
2. I/O subsystem power supply 2, U0.dd-V2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1521 Power supply 2 fault
1. I/O subsystem power supply 2, U0.dd-V2.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1522 Power supply 2 non-power fault
1. I/O subsystem power supply 2, U0.dd-V2.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1523 Power supply 2 domain fault
1. I/O subsystem power supply 2, U0.dd-V2.
2. I/O subsystem backplane, U0.dd-P1.
1nn1 1527 Power supply 2 thermal fault
1. Check for obstructions to the air flow around
the I/O subsystem.
2. I/O subsystem power supply 2, U0.dd-V2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1B01 +12 V load fault
1. Replace power supply 1, U0.dd-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1B02 +5 V load fault
1. Replace power supply 1, U0.dd-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1B03 +3.3 V load fault
1. Replace power supply 1, U0.dd-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 1B04 -12 V load fault
1. Replace power supply 1, U0.dd-V1.
2. If power supply 2 is present, use power
supply 1 that was removed to replace power
supply 2.
3. I/O subsystem backplane, U0.dd-P1.
1nn1 2600 Pgood fault
I/O subsystem backplane, U0.dd-P1.
1nn1 2603 Power domain fault
I/O subsystem backplane, U0.dd-P1.
1nn1 2605 Pgood 1.8 V fault
I/O subsystem backplane, U0.dd-P1.
1nn1 2606 Pgood 2.5 V fault
I/O subsystem backplane, U0.dd-P1.
1nn1 3100 I2C controller fault
I/O subsystem backplane, U0.dd-P1.
Chapter 5. Error code to FRU index
135
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...