Table 15. Firmware error codes (continued)
Error code Description
Action or
possible failing FRU
20D0 9008 Invalid subsystem serial number found in VPD.
1. Power off, and then power on the system.
2. If the error persists, call service support.
20D1 0001 Failed to send state-change message to service
processor.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0002 Failed to disable heartbeat alarm.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0003 Failed to send boot status.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0004 Failed to locate service processor device tree
node.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0005 Failed to reboot system.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0006 Failed to reboot a partition.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0007 Failed to set PCI read/write permissions array.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0008 Failed to set PCI read/write permissions array
for slot.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 0009 Missing or invalid subsystem serial number.
1. Check for system firmware updates. Apply
update if available.
2. If a location code is shown with this error
code, replace the part at that location.
3. Call service support.
Note:
The location code identifies the failing
subsystem.
20D1 000A Failed to send boot failed message to service
processor.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 000B Failed to reset PCI read/write permissions array. 1. Check for system firmware updates. Apply
update if available.
2. Call service support.
20D1 000C Failed to send LMB-TABLE-INFO mailbox repair. 1. Check for system firmware updates. Apply
update if available.
2. Call service support.
140
NAS Gateway 500 Service Guide
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...