Table 15. Firmware error codes (continued)
Error code Description
Action or
possible failing FRU
2201 0001 PCI Auto LANstreamer token-ring adapter failed
to complete hardware initialization.
Replace the adapter.
See “Checkpoint and error code index” on
page 127 for location code information related to
this error. Also see “Replacing a PCI-X adapter”
on page 126.
2201 1001 PCI token-ring adapter failed to complete
hardware initialization.
Replace the adapter.
See “Checkpoint and error code index” on
page 127 for location code information related to
this error. Also see “Replacing a PCI-X adapter”
on page 126.
25A0 0001 Cache L2 controller failure
1. Replace the processor card.
Location code: U0.1-P1-C1
2. Replace the CEC backplane assembly.
Location code: U0.1-P1.
25A1 0001 Cache L2 SRAM failure
1. Replace the processor card.
Location code: U0.1-P1-C1
25A8 0xxx
Description:
NVRAM problems
Action:
Errors reported against NVRAM can be caused by low battery voltage and (more rarely)
power outages that occur during normal system usage. With the exception of the 25A80000 error,
these errors are warnings that the NVRAM data content had to be reestablished and do not
require any FRU replacement unless the error is persistent. When one of these errors occurs, any
system customization (for example, boot device list) information has been lost, the system might
need to be reconfigured.
If the error is persistent, replace CEC backplane
Location code: U0.1-P1
25A8 0000 Initialization failed; device test failed.
Refer to Action under error code 25A80xxx.
25A8 0100 NVRAM data validation check failed.
Turn off, and then turn on system unit and retry
the operation before replacing any system
component.
Refer to Action under error code 25A80xxx.
25A8 0201 Unable to expand target partition - saving
configuration variable.
Refer to Action under error code 25A80xxx.
25A8 0202 Unable to expand target partition - writing error
log entry.
Refer to Action under error code 25A80xxx.
25A8 0203 Unable to expand target partition - writing VPD
data.
Refer to Action under error code 25A80xxx.
25A8 0210 Setenv/$Setenv parameter error - name
contains a null character.
Refer to Action under error code 25A80xxx.
25A8 0211 Setenv/$Setenv parameter error - value contains
a null character.
Refer to Action under error code 25A80xxx.
Chapter 5. Error code to FRU index
147
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...