Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
4067 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
Reboot the system in slow mode. Run
diagnostics, then go to
″
MAP 0235: System
Array Self-Repair Problem Resolution
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
4067 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
CEC backplane, U0.1-P1
4067 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
CEC backplane, U0.1-P1
4067 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
4067 0B03 Problem with internal RIO interface (I/O slot 0,
I/O port 3)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
4067 0B40 Problem with controller chip on CEC backplane
1. CEC backplane, U0.1-P1.
2. Call service support.
4067 0BF0 Problem with RIO interface (I/O slot 0, I/O port
3)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
4067 0C10 Processor 0 configuration error: VPD mismatch
for processor card 0. (Service processor code
problem.)
1. Check for system firmware updates.
2. Call service support.
4067 0C11 Processor 1 configuration error: VPD mismatch
for processor card 1. (Service processor code
problem.)
1. Check for system firmware updates.
2. Call service support.
4067 0CA5 Invalid system configuration
1. Check that the processor cards and DIMMs
are properly installed and configured.
2. If there are any FRUs listed in the service
processor error log entry, replace them one
at a time.
3. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
4067 0CA6 No usable memory left in the system. The
system must be rebooted.
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4067 0CA9 Incorrect or incompatible DIMMs are installed.
Check that the DIMMs are properly configured
and are the right type for the system.
4067 0CAA System memory exceeds the limit for this
system type and model.
Remove the DIMMs until the memory does not
exceed the limit for this system type and model.
Chapter 5. Error code to FRU index
167
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...