Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
406A 0101 Memory extender 2 on processor card 1
Processor card,
Location code: U0.1-P1-C1
406A 0130 Memory extender 0 on processor card 2
Processor card,
Location code: U0.1-P1-C2
406A 0131 Memory extender 2 on processor card 2
Processor card,
Location code: U0.1-P1-C2
406A 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
Reboot the system in slow mode. Run
diagnostics, and then go to
″
MAP 0235: System
Array Self-Repair Problem Resolution
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
406A 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
Reboot the system in slow mode. Run
diagnostics, then go to
″
MAP 0235: System
Array Self-Repair Problem Resolution
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
406A 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
CEC backplane, U0.1-P1
406A 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
CEC backplane, U0.1-P1
406A 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
406A 0B03 Problem with internal RIO interface (I/O slot 0,
I/O port 3)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
406A 0B40 Problem with controller chip on CEC backplane
1. CEC backplane, U0.1-P1.
2. Call service support.
406A 0BF0 Problem with RIO interface (I/O slot 0, I/O port
3)
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
406A 0C10 Processor 0 configuration error: VPD mismatch
for processor card 0. (Service processor code
problem.)
1. Check for system firmware updates.
2. Call service support.
406A 0C11 Processor 1 configuration error: VPD mismatch
for processor card 1. (Service processor code
problem.)
1. Check for system firmware updates.
2. Call service support.
178
NAS Gateway 500 Service Guide
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...