Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
406A 0CA5 Invalid system configuration
1. Check that the processor cards and DIMMs
are properly installed and configured.
2. If there are any FRUs listed in the service
processor error log entry, replace them one
at a time.
3. Go to “MAP 1540: Problem Isolation
Procedures” on page 69.
406A 0CA6 No usable memory left in the system. The
system must be rebooted.
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
406A 0CA9 Incorrect or incompatible DIMMs are installed.
Check that the DIMMs are properly configured
and are the right type for the system.
406A 0CAA System memory exceeds the limit for this
system type and model.
Remove the DIMMs until the memory does not
exceed the limit for this system type and model.
406A 0EA0 MOPS service processor code error.
1. Check for system firmware updates.
2. Call service support.
406A 0EA1 Operating system code on main processor
1. Check for operating system code updates.
2. If there are other symptoms, go (one
symptom at a time) to the “Quick Entry MAP”
on page 40 and follow the instructions.
3. Call service support.
406A 0EA2 PRD code on service processor error.
1. Check for system firmware updates.
2. Call service support.
406A 0EA4 The service processor detected a problem but
was unable to isolate the source.
Call service support.
406A 0EAF Service processor code and system type are
unknown.
1. Check for system firmware updates.
2. Call service support.
406A 0EB0 JTAG problem
Go to “MAP 1541: JTAG Problem Isolation” on
page 71.
406A 0EB1 Attention line 0 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB2 Attention line 1 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB3 Attention line 2 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB4 Attention line 3 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB5 Attention line 4 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB6 Attention line 5 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB7 Attention line 6 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406A 0EB8 Attention line 7 stuck fault
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
Chapter 5. Error code to FRU index
179
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...