Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
406B 0018 DIMM fault
DIMM
Location code: U0.1-P1-C2-M8
406B 0019 DIMM fault
DIMM
Location code: U0.1-P1-C2-M6
406B 001A DIMM fault
DIMM
Location code: U0.1-P1-C2-M1
406B 001B DIMM fault
DIMM
Location code: U0.1-P1-C2-M3
406B 001C DIMM fault
DIMM
Location code: U0.1-P1-C2-M7
406B 001D DIMM fault
DIMM
Location code: U0.1-P1-C2-M5
406B 001E DIMM fault
DIMM
Location code: U0.1-P1-C2-M2
406B 001F DIMM fault
DIMM
Location code: U0.1-P1-C2-M4
406B 00B0 Bus controller failure
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
406B 00B1 Bus controller failure
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
406B 00B3 MCM/VPD problem detected.
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
406B 00B4 MCM/VPD problem detected.
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
406B 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
Go to “MAP 1540: Problem Isolation Procedures”
on page 69.
406B 00D1 Informational message
Informational message
406B 0100 Memory extender 0 on processor card 1
Processor card,
Location code: U0.1-P1-C1
406B 0101 Memory extender 2 on processor card 1
Processor card,
Location code: U0.1-P1-C1
406B 0130 Memory extender 0 on processor card 2
Processor card,
Location code: U0.1-P1-C2
406B 0131 Memory extender 2 on processor card 2
Processor card,
Location code: U0.1-P1-C2
406B 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
Reboot the system in slow mode. Run
diagnostics, and then go to
″
MAP 0235: System
Array Self-Repair Problem Resolution
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems
.
Chapter 5. Error code to FRU index
181
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...