Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
4503 30AA
Description:
2 GB DIMM fault
Action:
This error code indicates that the memory repeat gard function has deconfigured a quad of
memory. Do the following:
1. Go to the memory configuration/deconfiguration menu, located under the system information
menu in the service processor menus.
Look at the status of the DIMMs. If any of the DIMMs has a status of
manually deconfigured
,
reconfigure the DIMMs and boot the system to the SMS menus. Power off the system using the
white power button and look again at the status of the DIMMs.
If all of the DIMMs are configured in the memory configuration/deconfiguration menu, the
problem has been resolved.
If any of the DIMMs has a status of
deconfigured by the system
, either before or after the boot
to the SMS menus, go to step 2.
2. Replace the quad of memory containing the DIMM specified by the location code. The entire
quad of memory must be replaced.
4504 26F6 1-way processor card fault
Replace the processor card specified by the
location code.
4504 26F7 2-way processor card fault
Replace the processor card specified by the
location code.
4504 26F8 1-way processor card fault
Replace the processor card specified by the
location code.
4504 26FA 2-way processor card fault
Replace the processor card specified by the
location code.
4504 26FB 2-way processor card fault
Replace the processor card specified by the
location code.
4504 26FD 1-way processor card fault
Replace the processor card specified by the
location code.
4504 26FE 2-way processor card fault
Replace the processor card specified by the
location code.
4504 26FF 1-way processor card fault
Replace the processor card specified by the
location code.
4504 301A 128 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 301B 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 301C 256 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 301D 512 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 301E 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 302E 2 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 302F 256 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 303B 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
Chapter 5. Error code to FRU index
207
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...