Table 16. Service processor error codes (continued)
Error code Description
Action or
possible failing FRU
4504 303C 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 303D 2 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 309A 128 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 309B 256 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 309C 256 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 309D 512 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 309E 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 309F 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4504 30AA 2 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4505 26F6 1-way processor card fault
Replace the processor card specified by the
location code.
4505 26F7 2-way processor card fault
Replace the processor card specified by the
location code.
4505 26F8 1-way processor card fault
Replace the processor card specified by the
location code.
4505 26FA 2-way processor card fault
Replace the processor card specified by the
location code.
4505 26FB 2-way processor card fault
Replace the processor card specified by the
location code.
4505 26FD 1-way processor card fault
Replace the processor card specified by the
location code.
4505 26FE 2-way processor card fault
Replace the processor card specified by the
location code.
4505 26FF 1-way processor card fault
Replace the processor card specified by the
location code.
4505 301A 128 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4505 301B 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4505 301C 256 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4505 301D 512 MB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4505 301E 1 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
4505 302E 2 GB DIMM fault
Go to “MAP 1240: Memory Problem Resolution”
on page 52.
208
NAS Gateway 500 Service Guide
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...