To change the memory configuration, select the number of the DIMM. The DIMM state will change from
configured
to
deconfigured
or from
deconfigured
to
configured
.
In the previous example menu, each line shows two DIMMs and indicates whether they are configured.
To enable or disable Memory Repeat Gard, use menu option 77 of the Memory
Configuration/Deconfiguration Menu.
To enable or disable runtime recoverable error repeat gard, use option 78 of the memory
configuration/deconfiguration menu.
The failure history of each DIMM is retained. If a DIMM with a history of failures is brought back online
by disabling Repeat Gard, it remains online if it passes testing during the boot process. However, if
Repeat Gard is enabled, the DIMM is taken offline again because of its history of failures.
v
Power Control Network Utilities Menu
POWER CONTROL NETWORK UTILITIES MENU
1. Lamp Test for all Operator Panels
2. Display I/O Type
3. Change I/O Type
98. Return to Previous Menu
0>
–
Lamp Test for All Operator Panels
Selecting this option tests the indicators on the operator panel by causing them to blink on and off
for approximately 30 seconds.
Note:
SCSI and Ethernet LEDs do not blink.
–
Display I/O Type
This option is not available on this system.
–
Change I/O Type
Use this option to change the I/O type after a service action or configuration change, if the I/O type
is incorrect. If this option is chosen, you will be asked to type
A3
for the I/O type of the PCI riser card
that has been replaced or is present in the system. If the value is not valid, a failure message is
displayed on the console. Press Enter to return to the Power Control Network Utilities Menu.
272
NAS Gateway 500 Service Guide
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...