Specifications
This section contains system specifications for the NAS Gateway 500.
Note:
Refer to the
7014 Series Model T00 and T42 Rack Installation and Service Guide
, for information
on cabling power from the rack to the I/O subsystem.
Table 7. Specifications for the NAS Gateway 500
Dimensions
Height
178 mm (7.0 in., 4 EIA units)
Width
482.6 mm (19.0 in.)
Depth
641.4 mm (25.25 in.)
Weight
Minimum configuration
34.92 kg (78.70 lbs)
Maximum configuration
39.03 kg (87.49 lbs)
Electrical
Power source loading (typical in kVA)
2-way processor: 0.348, 4-way processor: 0.522
Power source loading (max. in kVA)
2-way processor: 0.522, 4-way processor: 0.783
Voltage range (V AC)
100 to 127 or 200 to 240 (autoranging)
Frequency (hertz)
50 / 60
Voltage range (V dc)
Not supported
Thermal output (typical)
2-way processor: 1129 Btu/hr, 4-way processor: 1693 Btu/hr
Thermal output (max.)
2-way processor: 1693 Btu/hr, 4-way processor: 2540 Btu/hr
Power input requirements (typical)
2-way processor: 330 watts, 4-way processor: 500 watts
Power input requirements (max.)
2-way processor: 500 watts, 4-way processor: 750 watts
Power factor - U.S., World Trade, Japan
0.96
Inrush current
²
50 amps
Maximum altitude
³
,
⁴
2135 m (7000 ft)
Temperature requirements
³
Operating
5 to 35°C (41 to 95°F)
Humidity requirements
⁴
Operating
(Noncondensing)
8 to 80%
Wet bulb
27°C (80°F)
Noise emissions
1, 5, 6
Operating
L
WAd
6.1 bels
<L
pA
>
m
44 dBA
Installation and air flow
Maintenance of service clearance will allow proper air flow.
1. Noise emission notes:
a. L
WAd
is the declared sound power emission level for a production series of machines.
b. L
pAm
is the mean value of the sound pressure emission levels at the operator position (if any) for a production series of
machines.
c. <L
pA
>
m
is the mean value of the space-averaged sound pressure emission levels at the one-meter positions for a production
series of machines.
d. N/A = Not Applicable (no operator position).
e. All measurements are made in accordance with ISO DIS 779 and reported in conformance with ISO DIS 7574/4.
2. Inrush currents occur only at initial application of power; no inrush occurs during normal power off-on cycle.
3. The upper limit of the dry bulb temperature must be derated 1°C per 137 m (450 ft) above 915 m (3000 ft).
4. The upper limit of the wet bulb temperature must be derated 1°C per 274 m (900 ft) above 305 m (1000 ft).
5. Levels are for a single system installed in a T00 or T42 32-EIA rack with the center of the unit approximately 1500 mm (59 in.) off
the floor.
6. Levels apply to the following hardware configuration: 2-way 1 gigahertz processor, 3 hard files, 2048 gigabytes of RAM,
redundant system (two 645-watt power supplies, 2 processor fans).
7. All measurements made in accordance with ISO 7779 and declared in conformance with ISO 9296.
Chapter 1. Reference information
29
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...