Step 1542-1
1. Ensure that the diagnostics and the operating system are shut down.
2. Turn off the power.
3. Select slow boot mode (select
Disable Fast Boot
) on the System Power Control menu from the
service processor main menu.
4. Turn on the power.
5. Insert the diagnostic CD-ROM into the CD-ROM drive.
Does the CD-ROM appear to operate correctly?
NO
Go to “Boot problems or concerns” on page 122.
YES
Go to “Step 1542-2”.
Step 1542-2
1. When the keyboard indicator is displayed (the word
keyboard
), press 5 on the firmware console.
2. Enter the appropriate password when you are prompted to do so.
Is the Please define system console panel displayed?
NO
Go to “Step 1542-3”.
YES
Go to “Step 1542-4”.
Step 1542-3
The system is unable to boot standalone diagnostics.
Check the service processor error log and the operator panel for additional error codes resulting from the
slow boot in “Step 1542-1”. Did the slow boot generate a different error code from the one that originally
sent you to MAP 1542?
NO
It appears that you have a processor subsystem problem. Call service support.
This ends the
procedure
.
YES
Restore fast-boot mode (select
Enable Fast Boot
) on the System Power Control menu from the
service processor main menu. Go to “Checkpoint and error code index” on page 127 and follow
the actions for the new error code.
Step 1542-4
The system stopped with the
″
Please define system console
″
prompt appearing on the system console.
Standalone diagnostics can be booted. Perform the following:
1. Follow the instructions on the panel to select the system console.
2. When the Diagnostic Operating Instructions panel is displayed, press Enter.
3. If the terminal type has not been defined, you will get a message saying “The terminal is not properly
initialized. Please enter a terminal type and press Enter.” Select a terminal type from the on screen list
which is supported by your console. This is a separate and different operation from selecting the
firmware console.
4. Select
Advanced Diagnostic Routines
.
5. When the Diagnostic Mode Selection menu is displayed, select
System Verification
to run diagnostics
on all resources.
Did running diagnostics produce a different symptom?
NO
Go to substep 6 on page 74.
Chapter 3. Maintenance Analysis Procedures (MAPs)
73
Summary of Contents for TotalStorage NAS Gateway 500
Page 1: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 2: ......
Page 3: ...IBM TotalStorage NAS Gateway 500 Service Guide GY27 0418 00 ...
Page 16: ...xiv NAS Gateway 500 Service Guide ...
Page 20: ...xviii NAS Gateway 500 Service Guide ...
Page 36: ...System logic flow Note Not all components are supported 16 NAS Gateway 500 Service Guide ...
Page 52: ...32 NAS Gateway 500 Service Guide ...
Page 58: ...38 NAS Gateway 500 Service Guide ...
Page 112: ...92 NAS Gateway 500 Service Guide ...
Page 266: ...246 NAS Gateway 500 Service Guide ...
Page 326: ...306 NAS Gateway 500 Service Guide ...
Page 353: ...Chapter 11 Removal and replacement procedures 333 ...
Page 392: ...372 NAS Gateway 500 Service Guide ...
Page 402: ...382 NAS Gateway 500 Service Guide ...
Page 412: ...392 NAS Gateway 500 Service Guide ...
Page 440: ...420 NAS Gateway 500 Service Guide ...
Page 446: ...426 NAS Gateway 500 Service Guide ...
Page 448: ...428 NAS Gateway 500 Service Guide ...
Page 466: ...446 NAS Gateway 500 Service Guide ...
Page 469: ......
Page 470: ... Printed in U S A GY27 0418 00 ...
Page 471: ...Spine information IBM TotalStorage NAS Gateway 500 NAS Gateway 500 Service Guide GY27 0418 00 ...