Chapter 64. RBM Settings configuration mode
This chapter provides an alphabetic listing of commands that are available in RBM
Settings configuration mode. All of the commands that are listed in “Common
commands” on page 2 and most, but not all, of the commands that are listed in
Chapter 114, “Monitoring commands,” on page 949 are also available in RBM
configuration mode.
To enter this configuration mode, use the Global
rbm
command. In this
configuration mode, you can define both RBM settings as well as the global
password policy for all locally-defined users.
v
To view the current configuration, use the
show
command.
v
To restore default settings, use the
reset
command.
v
To exit this configuration mode and save configuration changes to the running
configuration, use the
exit
command. When you save changes to the running
configure, these changes takes affect immediately. At this point, the new settings
could disable access to the DataPower appliance for any user who does not have
an active session (WebGUI, command line, Telnet, or serial port connection). In
other words, the changes could disable future access through any of the
following methods:
– Any user who attempts to access the appliance through the WebGUI
– Any user who attempts to access the appliance through the command line
– Any user who attempts to access the appliance through a Telnet session
– Any user who attempts to access the appliance through the serial port
connection (WebGUI or command line)
apply-cli
Specifies whether the RBM policy applies to command line access.
Syntax
apply-cli
{
on
|
off
}
Parameters
on
Applies the RBM policy to command line access. The access profile applies
to both WebGUI and command line access.
off
(Default) Does not apply the RBM policy to command line access. The
access profile applies to WebGUI access only. Command line access is
controlled by the specified command groups for the user group and by the
specified user accounts for application domains.
Guidelines
The
apply-cli
command controls whether the RBM policy applies to both WebGUI
access and command line access or applies to WebGUI access only. When enabled,
command groups assignment that is part of the User Group configuration and user
access that is part of Application Domain configuration are ignored.
Note:
Do not enable this option when the authentication method, as defined with
the
au-method
command, is
client-ssl
. If you enable this option and use SSL
© Copyright IBM Corp. 1999, 2008
581
Summary of Contents for WebSphere XS40
Page 1: ...WebSphere DataPower XML Security Gateway XS40 Command Reference Version 3 7 2 ...
Page 2: ......
Page 3: ...WebSphere DataPower XML Security Gateway XS40 Command Reference Version 3 7 2 ...
Page 44: ...18 Command Reference ...
Page 194: ...168 Command Reference ...
Page 198: ...172 Command Reference ...
Page 206: ...180 Command Reference ...
Page 210: ...184 Command Reference ...
Page 222: ...196 Command Reference ...
Page 232: ...206 Command Reference ...
Page 238: ...212 Command Reference ...
Page 268: ...242 Command Reference ...
Page 272: ...246 Command Reference ...
Page 276: ...250 Command Reference ...
Page 288: ...262 Command Reference ...
Page 292: ...266 Command Reference ...
Page 298: ...272 Command Reference ...
Page 320: ...294 Command Reference ...
Page 322: ...296 Command Reference ...
Page 340: ...314 Command Reference ...
Page 344: ...318 Command Reference ...
Page 352: ...326 Command Reference ...
Page 360: ...334 Command Reference ...
Page 368: ...342 Command Reference ...
Page 376: ...350 Command Reference ...
Page 386: ...360 Command Reference ...
Page 392: ...366 Command Reference ...
Page 396: ...370 Command Reference ...
Page 402: ...376 Command Reference ...
Page 404: ...378 Command Reference ...
Page 408: ...382 Command Reference ...
Page 446: ...420 Command Reference ...
Page 450: ...424 Command Reference ...
Page 456: ...430 Command Reference ...
Page 520: ...494 Command Reference ...
Page 536: ...510 Command Reference ...
Page 550: ...524 Command Reference ...
Page 584: ...558 Command Reference ...
Page 600: ...574 Command Reference ...
Page 605: ... timeout 500 Chapter 63 RADIUS configuration mode 579 ...
Page 606: ...580 Command Reference ...
Page 650: ...624 Command Reference ...
Page 668: ...642 Command Reference ...
Page 704: ...678 Command Reference ...
Page 714: ...688 Command Reference ...
Page 726: ...700 Command Reference ...
Page 734: ...708 Command Reference ...
Page 752: ...726 Command Reference ...
Page 756: ...730 Command Reference ...
Page 804: ...778 Command Reference ...
Page 880: ...854 Command Reference ...
Page 892: ...866 Command Reference ...
Page 912: ...886 Command Reference ...
Page 918: ...892 Command Reference ...
Page 940: ...914 Command Reference ...
Page 946: ...920 Command Reference ...
Page 974: ...948 Command Reference ...
Page 1004: ...978 Command Reference ...
Page 1030: ...1004 Command Reference ...
Page 1032: ...1006 Command Reference ...
Page 1065: ......
Page 1066: ... Printed in USA ...