IBM System x3750 M4

4

Manageability and security

Powerful systems management features simplify local and remote management of the x3750 M4:

The server includes an Integrated Management Module II (IMM2) to monitor server availability and 

perform remote management. Remote presence support is standard.
The integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved 

setup, configuration, and updates, and simplifies error handling.
Integrated Trusted Platform Module (TPM) 1.2 support enables advanced cryptographic functionality, 

such as digital signatures and remote attestation.
Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.

IBM Systems Director is included for proactive systems management. It offers comprehensive 

systems management tools that increases uptime, reduces costs, and improves productivity through 

advanced server management capabilities.
Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks 

when combined with a supported operating system.
Intel Trusted Execution Technology provides enhanced security through hardware-based resistance 

to malicious software attacks, allowing an application to run in its own isolated space, protected from 

all other software running on a system.

Energy efficiency

The x3750 M4 offers the following energy-efficiency features to save energy, reduce operational costs, 

increase energy availability, and contribute to a green environment:

Energy-efficient planar components help lower operational costs.

Highly efficient 750 W DC, 900 W AC, and 1400 W AC power supplies. 80 PLUS Platinum 

certification at high voltage AC.
The Intel Xeon processor E5-4600 product family offers better performance over the previous 

generation while fitting into the same thermal design power (TDP) limits.
Intel Intelligent Power Capability powers individual processor elements on and off as needed, to 

reduce power draw. 
Low-voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally 

constrained data centers and telecommunication environments.
Low-voltage 1.35 V DDR3 memory RDIMMs consume 19% less energy compared to 1.5 V DDR3 

RDIMMs.
Solid-state drives (SSDs) consume as much as 80% less power than traditional spinning 2.5-inch 

HDDs.
The server uses hexagonal ventilation holes, which is a part of IBM Calibrated Vectored Cooling™ 

technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient 

airflow through the system.
IBM Systems Director Active Energy Manager™ provides advanced data center power notification and 

management to help achieve lower heat output and reduced cooling needs.

Summary of Contents for x3750 M4

Page 1: ...Did you know The x3750 M4 has outstanding memory performance that is achieved by supporting three RDIMM per channel configurations at speeds up to 25 faster than the Intel specification while still ma...

Page 2: ...e for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core Intel Virtualization Technology integrates hardware level virtualization...

Page 3: ...redundant fans to provide availability for business critical applications The power source independent light path diagnostics panel and individual light path LEDs lead the technician to failed or fai...

Page 4: ...olated space protected from all other software running on a system Energy efficiency The x3750 M4 offers the following energy efficiency features to save energy reduce operational costs increase energ...

Page 5: ...ns of key components and connectors The following figure shows the front of the server Figure 2 Front view of the IBM System x3750 M4 The following figure shows the rear of the server Figure 3 Rear vi...

Page 6: ...IBM System x3750 M4 6 The following figure shows the locations of key components inside the server Figure 4 Inside view of the IBM System x3750 M4...

Page 7: ...ht 1 8 inch eXFlash SSD drives Maximum internal storage Up to 14 4 TB with 900 GB 2 5 inch SAS HDDs up to 16 TB with 1 TB 2 5 inch NL SAS SATA HDDs or up to 16 TB of SSDs using 512 GB 1 8 inch drives...

Page 8: ...rGuide IMM Advanced Upgrade software feature for remote presence are standard with the x3750 M4 Security features Power on password administrator s password Trusted Platform Module TPM Operating syste...

Page 9: ...E5 4650 8C 2 7 GHz 20 MB 1600 MHz 130W 2x 8 GB RDIMM 1333 MHz M5110e 1 GB F R5 4x 2 5 16 max Open 5 8 2 1x 1400W 8722 D1x 4x E5 4610 6C 2 4 GHz 15 MB 1333 MHz 95W 24x 8 GB RDIMM 1333 MHz M5110e 1xM511...

Page 10: ...MB 1333 MHz 95 W B1x and D1x 88Y7354 Intel Xeon E5 4617 6C 2 9 GHz 15 MB 1600 MHz 130 W A1x 88Y7330 Intel Xeon E5 4620 8C 2 2 GHz 16 MB 1333 MHz 95 W B2x 88Y7348 Intel Xeon E5 4640 8C 2 4 GHz 20 MB 1...

Page 11: ...Intel processor specification In some instances this configuration also results larger memory capacity that the specification recommends Tables cells highlighted with a grey background indicate when t...

Page 12: ...are available for the x3750 M4 server Table 5 Memory options Part number Feature code Description Maximum supported Models where used RDIMMs 49Y1406 8941 4 GB 1x 4 GB 1Rx4 1 35 V PC3L 10600 CL9 ECC D...

Page 13: ...per backplane Cannot be connected to the 8 drive backplane with a SAS expander When building drive backplane configurations all 1 8 inch SSD drive backplanes must be installed to the right of all 2 5...

Page 14: ...optional M5100 Series RAID 5 upgrades see below Supports RAID 6 and 60 with the optional M5100 Series RAID 6 Upgrade see below Supports 512 MB battery backed cache or 512 MB or 1 GB flash backed cach...

Page 15: ...x 1 standard C2x 1 standard 81Y4508 A22E ServeRAID M5100 Series Battery Kit 4 D1x 2 standard D2x 4 standard 81Y4546 A1X3 ServeRAID M5100 Series RAID 6 Upgrade 1 90Y4273 A2MC ServeRAID M5100 Series SSD...

Page 16: ...ps SAS 2 5 G2HS HDD 16 81Y9670 A283 IBM 300GB 15K 6Gbps SAS 2 5 SFF HS HDD 16 90Y8926 A2XB IBM 146GB 15K 6Gbps SAS 2 5 SFF G2HS HDD 16 2 5 inch 10K SAS Hot Swap HDDs 00AD075 A48S IBM 1 2TB 10K 6Gbps S...

Page 17: ...16 49Y5844 A3AU IBM 512GB SATA 2 5 MLC HS Enterprise Value SSD 16 90Y8643 A2U3 IBM 256GB SATA 2 5 MLC HS Enterprise Value SSD 16 90Y8648 A2U4 IBM 128GB SATA 2 5 MLC HS Enterprise Value SSD 16 1 8 inch...

Page 18: ...TA Multi Burner 46M0902 supports the following media and speeds for reading CD ROM 24X CD DA DAE 20X CD R 24X CD RW 24X DVD ROM single layer 8X DVD ROM dual layer 8X DVD R 4 7 GB 6X DVD R DL 4X DVD R...

Page 19: ...chanical Full height half length optional with riser card requires processor 2 Slot 3 PCIe 3 0 x8 x16 mechanical Full height half length optional with riser card requires processor 2 Slot 4 PCIe 3 0 x...

Page 20: ...IC mode vNIC mode Up to six vNICs up to three vNICs per one 10 Gb port Virtual Fabric mode or Switch Independent operational mode Virtual port bandwidth allocation in 100 Mbps increments Up to two vNI...

Page 21: ...dapter for IBM System x 8 47C9952 A47H Solarflare SFN5162F MR Dual Port 10GbE SFP Adapter 8 47C9960 A47J Solarflare SFN6122F LL Dual Port 10GbE SFP Adapter 8 42C1800 5751 QLogic 10Gb CNA for IBM Syste...

Page 22: ...t HBA for IBM System x 8 42D0485 3580 Emulex 8Gb FC Single port HBA for IBM System x 8 42D0510 3579 QLogic 8Gb FC Dual port HBA for IBM System x 8 42D0501 3578 QLogic 8Gb FC Single port HBA for IBM Sy...

Page 23: ...Y4377 A3DY IBM 1 2TB High IOPS MLC Mono Adapter 7 90Y4397 A3DZ IBM 2 4TB High IOPS MLC Duo Adapter 3 46C9078 A3J3 IBM 365GB High IOPS MLC Mono Adapter 7 46C9081 A3J4 IBM 785GB High IOPS MLC Mono Adapt...

Page 24: ...Supply 2 88Y7433 A2EA IBM System x 4S 750W High Efficiency 48 V DC Power Supply 2 88Y7367 A2A0 IBM Power Interposer for Redundant Power Supply 1 The power interposer is not needed if the processor and...

Page 25: ...ge files as virtual drives that are available for use by the server Uploading a diskette image to the IMM2 memory and mapping it to the server as a virtual drive Capturing blue screen errors Supported...

Page 26: ...100 127 nominal V AC 50 Hz or 60 Hz and System 20 A 10 A per power supply 200 208 nominal V AC 50 Hz or 60 Hz and System 10 A 200 240 nominal V AC 50 Hz or 60 Hz and System 9 A Minimum configuration 0...

Page 27: ...s scheduled to arrive at your customer s location within four hours after remote problem determination is completed We provide service around the clock every day including IBM holidays 9x5x4 hour A se...

Page 28: ...Zealand AS NZS CISPR 22 Class A IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 GB9254 Class A GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia GOST ME01...

Page 29: ...art 1 Part number Description Maximum quantity supported per one enclosure EXP3000 Hot Swap SATA 3 5 in Hard Drives 43W7630 1000 GB Dual Port Hot Swap SATA 12 49Y1940 IBM 2 TB 7200 Dual Port SATA 3 5...

Page 30: ...de 1 per one M5120 81Y4559 A1WY ServeRAID M5100 Series 1GB Flash RAID 5 Upgrade 1 per one M5120 81Y4508 A22E ServeRAID M5100 Series Battery Kit 1 per one M5120 81Y4546 A1X3 ServeRAID M5100 Series RAID...

Page 31: ...s that are not listed in this table See the IBM System Storage Interoperability Center for further information found at the following address http www ibm com systems support storage ssic Table 22 Ext...

Page 32: ...87651UX 1U Tape Drive Enclosure 8767HHX Half High Tape Drive Enclosure 87651NX 1U Tape Drive Enclosure with Nema 5 15P power cord 8767HNX Half High Tape Drive Enclosure with Nema 5 15P power cord Tap...

Page 33: ...O4 HH SAS drive rack mount kit 3572S5R TS2900 Tape Library with LTO5 HH SAS drive rack mount kit 35732UL TS3100 Tape Library Model L2U Driveless 35734UL TS3200 Tape Library Model L4U Driveless 46X2682...

Page 34: ...oE IBM System Networking 10 Gb top of rack switches 7309DRX IBM System Networking RackSwitch G8264CS Rear to Front 7309DFX IBM System Networking RackSwitch G8264CS Front to Rear 7309BD5 IBM System Net...

Page 35: ...1KX IBM 1500VA LCD 2U Rack UPS 230 V 53952AX IBM 2200VA LCD 2U Rack UPS 100 V 120 V 53952KX IBM 2200VA LCD 2U Rack UPS 230 V 53953AX IBM 3000VA LCD 3U Rack UPS 100 V 120 V 53953JX IBM 3000VA LCD 3U Ra...

Page 36: ...37 IBM 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX IBM Ultra Density Enterprise PDU C19 PDU WW 71762NX IBM Ultra Density Enterprise PDU C19 PDU WW 71763MU IBM Ultra...

Page 37: ...ack PDU with UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI...

Page 38: ...93084PX IBM 42U Enterprise Rack 93604EX IBM 42U 1200 mm Deep Dynamic Expansion Rack 93604PX IBM 42U 1200 mm Deep Dynamic Rack 93614EX IBM 42U 1200 mm Deep Static Expansion Rack 93614PX IBM 42U 1200 mm...

Page 39: ...fc 6694 IBM Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 fc 0726 IBM Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 IBM Local 1x8 Console Manager LCM8 Console cables 43V6147 3757 IBM...

Page 40: ...An FMV lease can help you get the solution you need now with low monthly payments that better align up front costs with the anticipated return on investment ROI from the technology Easy to acquire wit...

Page 41: ...rt entry portal docdisplay lndocid MIGR 5086346 IBM ServerProven hardware compatibility page for the x3750 M4 http www ibm com systems info x86servers serverproven compat us xseries 8722 html IBM Redb...

Page 42: ...erials for this IBM product and use of those Web sites is at your own risk IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligati...

Page 43: ...r common law trademarks in other countries A current list of IBM trademarks is available on the Web at http www ibm com legal copytrade shtml The following terms are trademarks of the International Bu...

Page 44: ...IBM System x3750 M4 44 Other company product or service names may be trademarks or service marks of others...

Reviews: