206
IBM eX5 Implementation Guide
Figure 5-21 RAID choices using the LSI configuration utility
The following options are presented:
Create IM Volume: Creates a RAID-1 array
RAID 1 drives are mirrored on a 1 to 1 ratio. If one drive fails, the other drive takes over
automatically and keeps the system running. However, in this configuration, you lose 50%
of your disk space with one of the drives being used as a mirrored image.
The stripe size is 64 Kb and cannot be altered.
This option also affects the performance on the drives, because all data has to be written
twice, once per drive. See the performance chart in Figure 5-22 on page 207 for details.
Create IME Volume: Creates a RAID-1E array
This option requires three drives, so it is not available in the HX5.
Create IS Volume: Creates a RAID-0 array
RAID 0 or the Integrated Striping (IS) volume, as shown in LSI, is one of the faster
performing disk arrays because read and write sectors of data are interleaved between
multiple drives. The downside to this configuration is immediate failure if one drive fails.
There is no redundancy.
In a RAID-0, you also keep the full size of both drives. Identical size drives are
recommended for performance, as well as data storage efficiency.
The stripe size is 64 Kb and cannot be altered.
We provide the instructions to create an array in 8.4, “Local storage considerations and array
setup” on page 385.
Summary of Contents for x3850 X5
Page 2: ......
Page 20: ...xviii IBM eX5 Implementation Guide...
Page 32: ...12 IBM eX5 Implementation Guide...
Page 34: ...14 IBM eX5 Implementation Guide...
Page 74: ...54 IBM eX5 Implementation Guide...
Page 136: ...116 IBM eX5 Implementation Guide...
Page 238: ...218 IBM eX5 Implementation Guide...
Page 392: ...372 IBM eX5 Implementation Guide...
Page 466: ...446 IBM eX5 Implementation Guide...
Page 560: ...540 IBM eX5 Implementation Guide...
Page 564: ...544 IBM eX5 Implementation Guide...
Page 578: ...IBM eX5 Implementation Guide IBM eX5 Implementation Guide...
Page 579: ......