215-801-000
Optical Drive Test Aborted
Explanation:
Optical Drive Test Aborted. Unable to communicate with driver.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Make sure that the DSA Diagnostic code is at the latest level.
2.
Run the test again.
3.
Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
4.
Run the test again.
5.
Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
6.
Run the test again.
Related Links:
v
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
215-802-000
Optical Drive Test Aborted
Explanation:
Optical Drive Test Aborted. A read error was encountered.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized. Rerun the test.
2.
Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
3.
Run the test again.
4.
If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
Related Links:
v
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
215-801-000 • 215-802-000
418
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Summary of Contents for X3850 X6
Page 1: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 2: ......
Page 3: ...System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 138: ...120 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 225: ...25 26 27 Chapter 5 Parts listing System x3850 X6 and x3950 X6 Types 3837 and 3839 207...
Page 1682: ...1664 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1706: ...1688 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1710: ...1692 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1728: ...1710 System x3850 X6 and x3950 X6 Types 3837 and 3839 Installation and Service Guide...
Page 1729: ......
Page 1730: ...Part Number 00FH434 Printed in USA 1P P N 00FH434...