Error
code
Description
Action
204-198-000
Test
aborted.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
2.
Update
the
BIOS
code
(see
3.
Look
in
the
test
log
(see
and
correct
any
other
errors.
204-210-000
Test
failed.
1.
Run
the
Quick
Memory
Test
Diagnostic
All
Banks
(see
2.
Update
the
BIOS
code
(see
3.
Look
in
the
test
log
(see
and
correct
any
other
errors.
215-xxx-000
Failed
CD
or
DVD
test.
1.
Run
the
test
again
with
a
different
CD
or
DVD.
2.
Reseat
the
following
components:
a.
CD
or
DVD
drive
cable
b.
Power
switch/LED
bracket
cable
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
CD
or
DVD
drive
cable
b.
CD
or
DVD
drive
c.
Power
switch/LED
bracket
cable
217-xxx-000
Failed
fixed
disk
test.
1.
Reseat
hard
disk
drive
1
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
1
cable
b.
Hard
disk
drive
1
217-xxx-001
Failed
fixed
disk
test.
1.
Reseat
hard
disk
drive
2
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
2
cable
b.
Hard
disk
drive
2
217-xxx-002
Failed
fixed
disk
test.
1.
Reseat
hard
disk
drive
3
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time:
a.
Hard
disk
drive
3
cable
b.
Hard
disk
drive
3
Chapter
2.
Diagnostics
41
Summary of Contents for xSeries 100
Page 1: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 106: ...90 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 110: ...94 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 120: ...104 IBM xSeries 100 Type 8486 Problem Determination and Service Guide...
Page 125: ......
Page 126: ...Part Number 31R2070 Printed in USA 1P P N 31R2070...