5.
Make
sure
to
reinstall
all
removable
components
on
the
system
board
and
reconnect
all
cables
to
the
system
board.
Reseat
the
power
supply
(Trained
service
technician
only)
Complete
the
following
steps:
1.
Remove
the
power
supply
from
the
server
(see
2.
Check
the
power
supply
for
damage
and
for
crimped
or
damaged
cables.
3.
Install
the
power
supply
in
the
server
(see
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
System-error
log
message
Action
A
system
NMI
was
detected.
Make
sure
that
the
system
software
is
operating
correctly
and
does
not
conflict
with
other
software;
the
system
software
has
created
a
software
NMI,
or
your
pressing
the
NMI
button
has
created
a
service
NMI.
Alert
accepted
by
remote
system
x
;
type:
y
,
ID:
z
Information
only.
Alert
accepted
from
system
x
;
type:
y
,
sender’s
ID:
z
Information
only.
Alert
ID
x
will
be
retried
by
sender;
when
accepted
by
a
remote
system,
it
will
have
a
different
ID.
Information
only.
Alert
not
accepted
from
system
x
;
type:
y
,
sender’s
ID:
z
Information
only.
Alert
not
accepted
by
remote
system
x
;
type:
y,
ID:
z
Information
only.
ASM
reset
--
reason
unknown
Information
only.
ASM
reset
due
to
watchdog
timeout
Information
only.
ASM
reset
due
to
x
,
instruction
fault:
y
Information
only.
ASM
reset
was
caused
by
restoring
default
values
Information
only.
ASM
reset
was
initiated
by
the
user
Information
only.
Cable:
Service
processor
not
present
1.
Check
the
pins
and
connectors
on
the
cable
that
connects
the
Remote
Supervisor
Adapter
II
or
other
service
processor
adapter
to
the
Remote
Supervisor
Adapter
connector
on
the
system
board
(see
the
illustration
on
page
for
the
location
of
the
connector).
2.
Reseat
the
cable
(both
ends)
from
the
Remote
Supervisor
Adapter
II
or
other
service
processor
adapter
to
the
Remote
Supervisor
Adapter
connector
on
the
system
board.
3.
Restart
the
server.
Chapter
5.
Diagnostics
101
Summary of Contents for xSeries 206m
Page 1: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 306m Types 8849 and 8491 Problem Determination and Service Guide...
Page 143: ......
Page 144: ...Part Number 31R1183 Printed in USA 1P P N 31R1183...