Diagnostic
Panel
LED
FRU/Action
PCI
B
LED
on
1.
Card
in
slots
3-5.
2.
Remove
all
PCI
adapters
from
slots
1-5.
3.
System
Board.
PCI
C
LED
on
1.
Remove
all
PCI
adapters
from
slots
1-5.
2.
System
Board.
PS1
LED
on
1.
Check
the
DC
Good
LED
on
power
supply
1.
If
off,
replace
power
supply
1.
2.
Power
Backplane.
PS2
LED
on
1.
Check
the
DC
Good
LED
on
power
supply
2.
If
off,
replace
power
supply
2.
2.
Power
Backplane.
OVER
LED
on
1.
Install
an
optional
additional
power
supply,
or
remove
optional
devices
from
the
server.
SMI
LED
on
1.
Reboot
the
system.
TEMP
LED
on
(Look
at
test
cases.)
1.
Ambient
temperature
must
be
within
normal
operating
specifications.
See“Features
and
specifications”
on
page
3.
2.
Ensure
fans
are
operating
correctly.
3.
Examine
System
Error
Log.
a.
System
over
recommended
temperature
1)
Information
LED
Panel
b.
DASD
over
recommended
temperature
(DASD
LED
also
on)
1)
Overheating
hard
drive
2)
DASD
Backplane
c.
System
over
recommended
temperature
for
CPU
X
(where
X
is
CPU
1,
2,
3,
or
4)
(CPU
LED
also
on)
1)
CPU
X
2)
System
Board
4.
If
the
CPU
LED
on
the
diagnostics
panel
is
also
on,
one
of
the
microprocessors
has
caused
the
error.
5.
System
Board
Diagnostic
error
codes
Note:
In
the
following
error
codes,
if
XXX
is
000
,
195
,
or
197,
do
not
replace
a
FRU.
The
description
for
these
error
codes
are:
000
The
test
passed.
195
The
Esc
key
was
pressed
to
abort
the
test.
197
This
is
a
warning
error
and
may
not
indicate
a
hardware
failure.
For
all
error
codes,
replace/follow
the
FRU/Action
indicated.
Error
Code/Symptom
FRU/Action
001-XXX-000
(Failed
core
tests)
1.
System
Board
001-XXX-001
(Failed
core
tests)
1.
System
Board
Symptom-to-FRU
index
129
Summary of Contents for xSeries 230 6RY
Page 1: ...Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 2: ......
Page 3: ...Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 20: ...12 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 38: ...30 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 48: ...40 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 126: ...118 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 132: ...124 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 167: ...Related service information 159...
Page 168: ...160 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 169: ...Related service information 161...
Page 170: ...162 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 171: ...Related service information 163...
Page 172: ...164 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 173: ...Related service information 165...
Page 174: ...166 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 184: ...176 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 185: ...Related service information 177...
Page 186: ...178 Hardware Maintenance Manual xSeries 230 Models 6RY 61Y...
Page 193: ......
Page 194: ...Part Number 19K6112 Printed in USA 1P P N 19K6112...