Note:
See
“System
replaceable
units”
on
page
144
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
202-XXX-001
(Failed
system
cache
test)
1.
Microprocessor
1
2.
System
board
202-XXX-002
(Failed
system
cache
test)
1.
Microprocessor
2
2.
System
board
206-XXX-000
(Failed
diskette
drive
test)
1.
Rerun
the
test
with
a
different
diskette.
2.
Make
sure
that
the
distance
between
monitors
and
diskette
drives
is
at
least
76
mm
(3
in.).
3.
Diskette
drive
cables.
4.
Diskette
drive.
5.
System
board.
215-XXX-000
(Failed
IDE
CD-ROM
drive
test)
1.
Rerun
the
test
with
a
different
CD-ROM.
2.
CD-ROM
drive
cables.
3.
CD-ROM
drive.
4.
System
board.
217-198-XXX
(Could
not
establish
drive
parameters)
1.
Check
cable
and
termination.
2.
Hard
disk
drive
backplane.
3.
Hard
disk
drive.
217-XXX-000
(Failed
hard
disk
drive
test)
Note:
If
RAID
is
configured,
the
hard
disk
drive
number
refers
to
the
RAID
logical
array.
v
Hard
disk
drive
1
217-XXX-001
(Failed
hard
disk
test)
Note:
If
RAID
is
configured,
the
hard
disk
number
refers
to
the
RAID
logical
array.
v
Hard
disk
drive
2
217-XXX-002
(Failed
hard
disk
test)
Note:
If
RAID
is
configured,
the
hard
disk
number
refers
to
the
RAID
logical
array.
v
Hard
disk
drive
3
217-XXX-003
(Failed
hard
disk
test)
Note:
If
RAID
is
configured,
the
hard
disk
number
refers
to
the
RAID
logical
array.
v
Hard
disk
drive
4
217-XXX-004
(Failed
hard
disk
test)
Note:
If
RAID
is
configured,
the
hard
disk
number
refers
to
the
RAID
logical
array.
v
Hard
disk
drive
5
217-XXX-005
(Failed
hard
disk
test)
Note:
If
RAID
is
configured,
the
hard
disk
number
refers
to
the
RAID
logical
array.
v
Hard
disk
drive
6
Chapter
6.
Symptom-to-FRU
index
121
Summary of Contents for xSeries 236 8841
Page 1: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 20: ...10 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 96: ...86 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 152: ...142 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 160: ...150 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 173: ...Appendix B Safety information 163...
Page 174: ...164 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 175: ...Appendix B Safety information 165...
Page 176: ...166 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 177: ...Appendix B Safety information 167...
Page 178: ...168 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 179: ...Appendix B Safety information 169...
Page 189: ...Appendix B Safety information 179...
Page 190: ...180 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 191: ...Appendix B Safety information 181...
Page 192: ...182 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 196: ...186 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 208: ...198 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 209: ......
Page 210: ...Part Number 25K8114 1P P N 25K8114...