Replacing
a
center
fan
(3
or
4)
Complete
the
following
steps
to
replace
hot-swap
fan
3
or
4:
Hot-swap fan
Center fan
3 or 4
Release
lever
1.
Read
the
safety
information
beginning
on
page
v
and
“Installation
guidelines”
on
page
11.
2.
Remove
the
cover.
See
“Removing
the
left-side
cover”
on
page
14.
The
LED
on
the
failing
fan
assembly
will
be
lit.
Attention:
To
ensure
proper
system
cooling,
do
not
remove
the
left-side
cover
for
more
than
30
minutes
during
this
procedure.
3.
Press
the
orange
fan-release
latch
in
the
direction
indicated
by
the
arrow
on
the
latch
to
open
the
release
lever.
4.
Pull
the
fan
out
of
the
server
using
the
release
lever.
5.
Press
the
orange
fan-release
latch
in
the
direction
indicated
by
the
arrow
on
the
latch
and
open
the
release
lever
on
the
replacement
fan.
6.
Position
the
replacement
fan
so
that
the
orange
fan-release
latch
is
away
from
you;
then,
slide
the
fan
into
the
server.
Press
the
release
latch
into
place
and
secure
the
fan
in
the
server.
7.
Make
sure
that
the
FAN
LED
on
the
diagnostic
LED
panel
(see
“Light
path
diagnostics
panel”
on
page
84)
is
not
lit.
If
the
FAN
LED
is
lit,
reseat
the
fan.
8.
Reinstall
the
server
cover.
See
“Installing
the
server
bezel
and
left-side
cover”
on
page
46.
Chapter
3.
Installing
options
19
Summary of Contents for xSeries 236 8841
Page 1: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 2: ......
Page 3: ...xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 20: ...10 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 96: ...86 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 152: ...142 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 160: ...150 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 173: ...Appendix B Safety information 163...
Page 174: ...164 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 175: ...Appendix B Safety information 165...
Page 176: ...166 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 177: ...Appendix B Safety information 167...
Page 178: ...168 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 179: ...Appendix B Safety information 169...
Page 189: ...Appendix B Safety information 179...
Page 190: ...180 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 191: ...Appendix B Safety information 181...
Page 192: ...182 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 196: ...186 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 208: ...198 xSeries 236 Type 8841 Hardware Maintenance Manual and Troubleshooting Guide...
Page 209: ......
Page 210: ...Part Number 25K8114 1P P N 25K8114...