background image

Power

 

cord

 

rating

 

IBM

 

power

 

cord

 

part

 

number

 

(2.5

 

m)

 

Used

 

in

 

these

 

countries

 

and

 

regions

 

16

 

A/250

 

V

 

ac

 

55H6643

 

Afghanistan,

 

Albania,

 

Algeria,

 

Andorra,

 

Angola,

 

Armenia,

 

Austria,

 

Azerbaijan,

 

Belarus,

 

Belgium,

 

Benin,

 

Bosnia

 

and

 

Herzegovina,

 

Bulgaria,

 

Burkina

 

Faso,

 

Burundi,

 

Cambodia,

 

Cameroon,

 

Cape

 

Verde,

 

Central

 

African

 

Republic,

 

Chad,

 

Comoros,

 

Congo

 

(Democratic

 

Republic

 

of),

 

Congo

 

(Republic

 

of),

 

Cote

 

D’Ivoire

 

(Ivory

 

Coast),

 

Croatia

 

(Republic

 

of),

 

Czech

 

Republic,

 

Dahomey,

 

Djibouti,

 

Egypt,

 

Equatorial

 

Guinea,

 

Eritrea,

 

Estonia,

 

Ethiopia,

 

Finland,

 

France,

 

French

 

Guyana,

 

French

 

Polynesia,

 

Gabon,

 

Georgia,

 

Germany,

 

Greece,

 

Guadeloupe,

 

Guinea,

 

Guinea

 

Bissau,

 

Hungary,

 

Iceland,

 

Indonesia,

 

Iran,

 

Kazakhstan,

 

Korea

 

(Democratic

 

Peoples

 

Republic

 

of),

 

Korea

 

(Republic

 

of),

 

Kyrgyzstan,

 

Laos

 

(Peoples

 

Democratic

 

Republic

 

of),

 

Latvia,

 

Lebanon,

 

Lithuania,

 

Luxembourg,

 

Macedonia

 

(former

 

Yugoslav

 

Republic

 

of),

 

Madagascar,

 

Mali,

 

Martinique,

 

Mauritania,

 

Mauritius,

 

Mayotte,

 

Moldova

 

(Republic

 

of),

 

Monaco,

 

Mongolia,

 

Morocco,

 

Mozambique,

 

Netherlands,

 

New

 

Caledonia,

 

Niger,

 

Norway,

 

Poland,

 

Portugal,

 

Reunion,

 

Romania,

 

Russian

 

Federation,

 

Rwanda,

 

Sao

 

Tome

 

and

 

Principe,

 

Saudi

 

Arabia,

 

Senegal,

 

Serbia,

 

Slovakia,

 

Slovenia

 

(Republic

 

of),

 

Somalia,

 

Spain,

 

Suriname,

 

Sweden,

 

Syrian

 

Arab

 

Replublic,

 

Tajikistan,

 

Tahiti,

 

Togo,

 

Tunisia,

 

Turkey,

 

Turkmenistan,

 

Ukraine,

 

Upper

 

Volta,

 

Uzbekistan,

 

Vanuatu,

 

Vietnam,

 

Wallis

 

and

 

Futuna,

 

Yugoslavia

 

(Federal

 

Republic

 

of),

 

Zaire

 

16

 

A/250

 

V

 

ac

 

36L8822

 

Denmark,

 

Liechtenstein,

 

Switzerland

 

16

 

A/250

 

V

 

ac

 

12J5122

 

Israel

 

16

 

A/250

 

V

 

ac

 

12J5126

 

Chile,

 

Italy,

 

Libyan

 

Arab

 

Jamahiriya

 

16

 

A/250

 

V

 

ac

 

12J5124

 

Bangladesh,

 

Lesotho,

 

Macao,

 

Maldives,

 

Namibia,

 

Nepal,

 

Pakistan,

 

Samoa,

 

South

 

Africa,

 

Sri

 

Lanka,

 

Swaziland,

 

Uganda

 

13

 

A/250

 

V

 

ac

 

12J5987

 

Abu

 

Dhabi,

 

Bahrain,

 

Botswana,

 

Brunei

 

Darussalam,

 

Channel

 

Islands,

 

Cyprus,

 

Dominica,

 

Gambia,

 

Ghana,

 

Grenada,

 

Guyana,

 

Hong

 

Kong,

 

Iraq,

 

Ireland,

 

Jordan,

 

Kenya,

 

Kuwait,

 

Liberia,

 

Malawi,

 

Malaysia,

 

Malta,

 

Myanmar

 

(Burma),

 

Nigeria,

 

Oman,

 

Qatar,

 

Saint

 

Kitts

 

&

 

Nevis,

 

Saint

 

Lucia,

 

Saint

 

Vincent

 

and

 

the

 

Grenadines,

 

Seychelles,

 

Sierra

 

Leone,

 

Singapore,

 

Sudan,

 

Tanzania

 

(United

 

Republic

 

of),

 

Trinidad

 

&

 

Tobago,

 

United

 

Arab

 

Emirates

 

(Dubai),

 

United

 

Kingdom,

 

Yemen,

 

Zambia,

 

Zimbabwe

 

15

 

A/250

 

V

 

ac

 

12J5128

 

Australia,

 

Fiji,

 

Kiribati,

 

Nauru,

 

New

 

Zealand,

 

Papua

 

New

 

Guinea

 

15

 

A/250

 

V

 

ac

 

01K9851

 

China

 

15

 

A/250

 

V

 

ac

 

49P2114

 

Brazil

 

15

 

A/250

 

V

 

ac

 

49P2082

 

India

 

15

 

A/250

 

V

 

ac

 

36L8884

 

Argentina,

 

Paraguay,

 

Uruguay

 

15

 

A/125

 

V

 

ac

 

01K9853

 

Japan

    

Appendix.

 

Notices

 

51

Summary of Contents for xSeries 365

Page 1: ...IBM xSeries 365 Type 8861 and 8862 Option Installation Guide ERserver...

Page 2: ......

Page 3: ...IBM xSeries 365 Type 8861 and 8862 Option Installation Guide ERserver...

Page 4: ...general information in Notices on page 45 Second Edition January 2004 Copyright International Business Machines Corporation 2003 All rights reserved US Government Users Restricted Rights Use duplicat...

Page 5: ...swap power supply 29 Replacing the battery 31 Replacing a hot swap fan 33 Replacing the memory cassette 34 Completing the installation 35 Installing the cover and bezel 35 Connecting the cables 36 Upd...

Page 6: ...MC Directive conformance statement 48 Taiwanese Class A warning statement 49 Chinese Class A warning statement 49 Japanese Voluntary Control Council for Interference VCCI statement 49 Power cords 49 I...

Page 7: ...alleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Page 8: ...Antes de instalar este producto lea la informaci n de seguridad L s s kerhetsinformationen innan du installerar den h r produkten vi IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...

Page 9: ...ce or reconfiguration of this product during an electrical storm v Connect all power cords to a properly wired and grounded electrical outlet v Connect to properly wired outlets any equipment that wil...

Page 10: ...drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation T...

Page 11: ...power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove...

Page 12: ...inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 10 CAUT...

Page 13: ...contains instructions for installing your server in a rack v Hardware Maintenance Manual and Troubleshooting Guide This document is in PDF on the IBM xSeries Documentation CD It contains information...

Page 14: ...ese statements indicate situations that can be potentially hazardous to you A caution statement is placed just before the description of a potentially hazardous procedure step or situation v Danger Th...

Page 15: ...swap power supply Remote Supervisor Adapter II SCSI backplane Hot swap fans Operator information panel Hot swap Hard disk drive Hard disk drive filler panel Hard disk drive air baffle CD ROM drive Bez...

Page 16: ...ining clips look for a lit retaining clip to locate a failed DIMM DIMM connector 1 DIMM connector 2 DIMM connector 3 DIMM connector 4 DIMM connector 5 DIMM connector 6 DIMM connector 7 DIMM connector...

Page 17: ...onnector 5 DIMM connector 6 DIMM connector 7 DIMM connector 8 DIMM connector 16 DIMM connector 15 DIMM connector 14 DIMM connector 13 DIMM connector 12 DIMM connector 11 DIMM connector 10 DIMM connect...

Page 18: ...4 bit PCI X slot 2 100 MHz 64 bit PCI slot 1 33 MHz 64 bit Ethernet 2 USB 2 J15 Ethernet 1 USB 1 J12 RXE expansion J11 Mouse J9 PCI switch card cable J18 Battery Remote Supervisor Adapter II cable J16...

Page 19: ...rride J20 The default position is pins 1 and 2 Changing the position of this jumper to pins 2 and 3 bypasses the power on password check Changing the position of this jumper does not affect the admini...

Page 20: ...h test LED Microprocessor 4 VRM error LED Microprocessor 3 VRM error LED Microprocessor 4 VRM connector Microprocessor 3 VRM connector Microprocessor 4 socket Microprocessor 3 socket Microprocessor 2...

Page 21: ...disk drive or SCSI backplane failure NR Nonredundant power mode NMI Nonmaskable interrupt SP Service processor error EXP Attached expansion I O failure LOG See event log or Remote Supervisor Adapter I...

Page 22: ...time Light path diagnostics might direct you to look for an LED that identifies the specific failing component on the internal boards See the illustrations in this chapter that identify the LEDs on th...

Page 23: ...p and hot plug components v The blue color on components and labels indicates touch points where a component can be gripped a latch moved and so on v For a list of supported options for your server go...

Page 24: ...tricity to build up around you v Handle the device carefully holding it by its edges or its frame v Do not touch solder joints pins or exposed circuitry v Do not leave the device where others can hand...

Page 25: ...Operating the server for more than 2 minutes with the top cover removed might damage server components 5 Press on the bezel retention tabs at the top edge of the bezel and pull the top of the bezel sl...

Page 26: ...ter it must be installed in slot 2 v If you install an IXA adapter it must be installed in slot 3 and you must set the IXA jumper on the I O board See page 7 for the location and setting of the IXA ju...

Page 27: ...the RAID adapter for any additional cabling instructions That documentation also provides information about installing the RAID software and configuring the RAID adapter For a list of supported RAID...

Page 28: ...the slot c Remove the expansion slot cover d Carefully grasp the adapter by its top edge or upper corners and align it with the connector on the PCI X board e If necessary remove the extension handles...

Page 29: ...is installed in the tray correctly If your server has an optional RAID adapter installed see the documentation that comes with the adapter for information about installing a hard disk drive Complete t...

Page 30: ...ring aside 4 Slide the drive out the front of the server 5 Slide the replacement drive into the bay 6 Align the holes in the side of the drive with the hole in each drive guide 7 Push each end of the...

Page 31: ...de install DIMMs in pairs in mirrored mode install DIMMs in quads or groups of 4 Each pair or quad must be of the same type capacity and speed v You must populate the DIMM connectors in the following...

Page 32: ...orts 8 DIMM memory board Bank 1 Bank 2 Bank 3 Bank 4 Port 1 Port 2 16 DIMM memory board Bank 1 Bank 5 Bank 3 Bank 7 Bank 2 Bank 6 Bank 4 Bank 8 Port 1 Port 2 v When you restart the server after adding...

Page 33: ...ezel on page 13 3 Open the two DIMM access doors on the top of the memory cassette A C D C P S 2 P S 1 4 Open the retaining clip on each end of the DIMM connector Attention To avoid breaking the DIMM...

Page 34: ...inished 9 If you have other options to install or remove do so now otherwise go to Completing the installation on page 35 Installing a microprocessor The following notes describe information that you...

Page 35: ...alled in microprocessor connector 1 U22 The microprocessor supports both the startup and application processes v If you install additional microprocessors in the server microprocessor 2 is installed i...

Page 36: ...the server will not turn on v Avoid touching the components and pins on the microprocessor Make sure that the microprocessor is completely and correctly seated in the socket Incomplete insertion migh...

Page 37: ...b Remove all fans See Replacing a hot swap fan on page 33 for instructions Chapter 2 Installing options 25...

Page 38: ...ay levers Microprocessor tray release latch d Open the microprocessor tray levers 2 e Pull out the microprocessor tray 3 Attention The microprocessor tray is heavy Pull the tray part way out of the se...

Page 39: ...oprocessors 3 and 4 5 Remove the microprocessor baffle from the empty microprocessor socket and store the microprocessor baffle for future use 6 Remove the protective cover tape or label from the surf...

Page 40: ...es its heat conducting capability and exposes the new microprocessor to overheating v If you need to remove the heat sink after installing it note that the thermal material might have formed a strong...

Page 41: ...ch is open then push the microprocessor tray into the server b Close the tray levers and make sure they are securely latched c Press the microprocessor tray release latch down d Reinstall the fans and...

Page 42: ...ing handle open Locking latch DC power LED green Fan LED amber AC power LED green Power supply 1 PS1 AC DC A C D C A C D C AC power connector cover Complete the following steps to install a hot swap p...

Page 43: ...ue with Completing the installation on page 35 Replacing the battery The following notes describe information that you must consider when replacing the battery in the server v When replacing the batte...

Page 44: ...at the positive symbol is facing away from you b Use one finger to press the top of the battery clip away from the battery c Press the battery into the socket until it clicks into place Make sure that...

Page 45: ...er see Removing the cover and bezel on page 13 Attention To ensure proper system cooling do not leave the top cover off the server for more than 2 minutes 3 Open the fan locking handle by sliding the...

Page 46: ...erverProven list at http www ibm com pc compat for a list of memory cassettes supported by the server Complete the following steps to replace the memory cassette in the server 1 Review the safety info...

Page 47: ...pins 6 Install DIMMs in the memory cassette you can use the DIMMs from the previous memory cassette See Installing memory modules on page 18 for the DIMM population order to use Note Use the Configura...

Page 48: ...rack cabinet 8 If you disconnected any power cords or external cables from the server reconnect the external cables first If you are adding any new peripheral devices see Connecting the cables for de...

Page 49: ...k Installation Instructions provided with the server The illustrations in this document might differ slightly from your hardware See the documentation that comes with any option you install for additi...

Page 50: ...N Note Another Ethernet connector is located on the Remote Supervisor Adapter II This port is used for specific supervisory functions and should not be confused with the Gigabit Ethernet connectors ab...

Page 51: ...d a hard disk drive see the documentation that comes with the RAID adapter for information about reconfiguring the disk arrays For information about setting up configuring and using the Remote Supervi...

Page 52: ...40 IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...

Page 53: ...r II ASM one rear v Remote Supervisor Adapter II USB reserved The following illustration shows the USB connector on the operator information panel on the front of the server USB connector The followin...

Page 54: ...100BASE TX and 1000BASE T Fast Ethernet standards require Category 5 or higher cabling For more information about the Ethernet controller see the User s Guide Keyboard connector Use this connector to...

Page 55: ...g illustration shows a serial connector 1 5 6 9 Connect a serial cable to this port to enable system management through a modem or connect a null modem cable to enable system management through a work...

Page 56: ...connector Connect the cable from the server monitor to this connector Attention Do not connect the ASM connector to the RXE Management Port on the server If you want to use the Remote Supervisor Adap...

Page 57: ...Y OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer...

Page 58: ...untries or both Microsoft Windows and Windows NT are trademarks of Microsoft Corporation in the United States other countries or both UNIX is a registered trademark of The Open Group in the United Sta...

Page 59: ...ibility gaskets and connectors which may contain lead and copper beryllium alloys that require special handling and disposal at end of life Before this unit is disposed of these materials must be remo...

Page 60: ...e equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any i...

Page 61: ...t may cause radio interference in which case the user may be required to take adequate measures Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council...

Page 62: ...a specific country or region are usually available only in that country or region Power cord rating IBM power cord part number 2 5 m Used in these countries and regions 15 A 125 V ac 12J5112 Antigua a...

Page 63: ...incipe Saudi Arabia Senegal Serbia Slovakia Slovenia Republic of Somalia Spain Suriname Sweden Syrian Arab Replublic Tajikistan Tahiti Togo Tunisia Turkey Turkmenistan Ukraine Upper Volta Uzbekistan V...

Page 64: ...52 IBM xSeries 365 Type 8861 and 8862 Option Installation Guide...

Page 65: ...lling 35 removing 13 D diskette drive replacing 18 drive CD ROM replacing 18 diskette replacing 18 E electronic emission Class A notice 48 Ethernet connector 42 F fan replacing 33 FCC Class A notice 4...

Page 66: ...r cords 49 supplies 29 power supply installing 29 LEDs 31 R related documents 1 Remote Supervisor Adapter II cable connector on I O board 6 external connectors 44 replacing CD ROM drive 18 RXE Expansi...

Page 67: ......

Page 68: ...Part Number 13N0344 Printed in USA 1P P N 13N0344...

Reviews: