Error
code
Description
Action
180-xxx-006
Failed
memory
card
LED
test.
1.
Reseat
the
following
components:
a.
Memory
card
b.
Microprocessor
tray
c.
I/O
board
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
(Trained
service
technician
only)
Microprocessor
tray
c.
I/O
board
180-xxx-007
Failed
power
supply
fan
LED
test.
1.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
supply
structure
c.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
180-xxx-008
Failed
I/O
board
LED
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
180-xxx-009
Failed
Active
™
PCI
LED
test.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
PCI-X
switch
card
assembly
b.
I/O
board
2.
Replace
the
components
listed
in
step
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
201-198-000
Memory
Test
Aborted:
Could
not
run
the
test;
suspect
microprocessor
tray
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
201-198-00n
Memory
Test
Aborted:
Could
not
run
the
test.
Note:
n
=
1-9
(programming
error).
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
Chapter
2.
Diagnostics
85
Summary of Contents for xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 181: ...V video connector 6 VRM LED 64 W Web site 1 weight 3 World Wide Web 1 Index 165...
Page 182: ...166 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 183: ......
Page 184: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...