background image

  

 

 

 

 

           
              The pump must be installed above the filter of the well. The minimal            
              distance between the upper edge of the last part of the filter and the lower    
              edge of the motor may not be less than 30 cm. 

 

                   

The pump may not dry run, without water. Dry run damages the           

            equipment. In this case the repair may be performed only against payment. 

To  prevent  potential  dry  run  the  pump  must  be  installed  at  such  depth  so  that  the 
lowest  dynamic  level  of  the  water  (water  level  established  during  continuous 
pumping at free outflow) is at least 2 m above the liquid feed port of the pump. 
If the efficiency of the well prevents such assembly (the well is not as efficient as the 
pump) then choose an option from the following: 

install smaller pump 

install a valve for constant reduction of the flow on the delivery pipeline, 

install a safety device against dry run to control the level of water table and in 
case of dry run to cut off the power supply to the unit. 

 

                                     

When lowering the pump into the well make sure that the feed  

                          cable of the pump is in at least 2m mounted to the delivery pipe with 
plastic  bands.  At  a  great  depth  where  the  pump  is  installed  the  cable  which  is  not 
mounted to the delivery pipe may break reason high weight of cable. 
 

I                       It is recommended to lift the pump additionally at a steel line so that in     
                         case of self-rewinding of the delivery pipeline the unit does not sink in   
                         the well. 
 

              Right over the pump install a non-return valve to protect the equipment    

              against the impact of the returning water. The non-return valve installed on 
the pump is an auxiliary valve, it may not be treated as the main valve. 

 
 

              The pump’s motor is filled with an environment-friendly oil. In case of a   
              motor breakdown the oil might be released to the well. 

 

                   

Before lowering the pump into a new well, the user should make sure   

             whether  the  drilling  company  which  executed  the  well  has  cleaned  it  by 
pumping  the  water  out.     When  executing  the  well  the  water  inside  the  protective 
pipe and inside the filter is contaminated with sludge and sand. 
Pumping the water containing sand reduces significantly the lifecycle of deep-well 
pumps. 

 

                     When setting the pressure switch and choosing the capacity o  
                     of pressure vessel it is necessary to comply with the rule that   
                     the pump motor may not switch on more often than 30 times 
per hour. More frequent switching on might overload and damage the 
motor. 

Summary of Contents for 3ti

Page 1: ...fully acquainted with operation instructions CAUTION The operation instructions constitute the main element of the purchase contract The user s failure to comply with these instructions is a default...

Page 2: ...ding or explosive substance e g gasoline nitro solvents petroleum etc food stuffs salt water Damage caused by pumping these types of liquids in not covered by the warranty Permitted temperature of the...

Page 3: ...orehole with a protective strip may damage the cable insulation This may damage the pump or cause electric shock to the operator Since the motor needs cooling during operation the diameter of the bore...

Page 4: ...bands At a great depth where the pump is installed the cable which is not mounted to the delivery pipe may break reason high weight of cable I It is recommended to lift the pump additionally at a stee...

Page 5: ...caused to people or objects resulting to feeding the pump without proper switch Pumps 4SDM MSC reason short length of cable are supplied with separate control box equipped with capacitor overload pro...

Page 6: ...surface on entire length The pump s support in one or several points may bend the pump and cause damage EQUIPMENT DISPOSAL The used product must be disposed as waste exclusively in selective waste co...

Page 7: ...two veins of the feed cable on the feeding strip only for three phase motors Too high resistance during the flow through the delivery pipe hose Check if the permitted lifting height for this specific...

Reviews: