background image

  

Maximum length of the cable in meter  depend of 

diameter separately wire of cable 

Voltage 

1 phase 

Power  
of  motor 
[kW] 

1  

mm

1,5 

mm

2,5 

mm

mm

mm

10 

mm

2

 

16 

mm

230-240 V 

0,37 

50 

75 

125 

 

 

 

 

230-240 V 

0,55 

40 

58 

94 

150 

 

 

 

230-240 V 

0,75 

30 

46 

74 

121 

174 

 

 

230-240 V 

1,1 

21 

32 

50 

86 

125 

215 

 

230-240 V 

1,5 

 

22 

37 

62 

90 

155 

245 

230-240 V 

2,2 

 

 

30 

45 

67 

115 

180 

 

                       Non-compliance with the above instructions on selection of cable   
                       reduces  the  voltage  excessively  and  in  consequence  overloads  and 

damage the motor. 
The pump is originally fitted with a short section of the cable. Depending on the user’s 
needs the cable is extended.  Water tight connections of cables must be executed by a 
person having proper knowledge and experience. The user should commission the 
assembly to a well driller company or can do it in a store he bought the pump.   
                             Non-professional connection and insulation of the cables may cause that the   
                             residual current devices will knock out, the motor will be flooded or the user  
                             may suffer electric shock. 

 

STORAGE: 
Clean pump must be stored in a dry place. 
             Make sure that the pump is placed on even surface on entire length. The  
             pump’s support in one or several points may bend the pump and cause   
             damage. 
EQUIPMENT DISPOSAL: 
               The used product must be disposed as waste exclusively in selective  
               waste collection organized by the Public Network of Electric and  
               Electronic  Waste  Collection  Points.  The  consumer  may  return  the  used 
equipment  to  the  distributor  of  electric  equipment,  at  least  free  of  charge  and 
directly provided that the equipment is of the right type and the same functionality 
as the newly purchased one. 

DECLARATION OF CONFORMITY EC (Module A): 
PHU DAMBAT 
address: Gawartowa Wola 38, 05-085 KAMPINOS, POLAND 
Pursuant  to  the  act  of  30th  August  2002  on  conformity  system  (Journal  of  Laws  of  2004  No. 
204,item 2087) with full responsibility we declare that the pumps are from series 4SG, 4SDm, 4SD, 
90QJD, 3ti, 4SKm, 4TP, 90MSC 
to  which  this  declaration  refers  comply  with  the  following  directives  of  the  European  Parliament 
and Council, relating to: 
1)  machines  no.  98/37/EC  (norms  applied:  PN-EN292-1:1991,  PN-EN292-2-1991/A1:1995,  PN-
EN 809:1999/AC:2004) 
2)  electromagnetic  compatibility  no.  89/336/EEC  (norms  applied:  PN-EN  55014-1:2004,  PN-EN 
61000-3-2:2004) 
3)  electric  equipment  applied  within  certain  limits  of  voltage  no.  73/23/EEC  (norms  applied:  PN-
EN 60335-1:2004, PN-EN 60335-2-41:2005) 
Adam Jastrz

ę

bski 

17.06.2008 

Summary of Contents for 3ti

Page 1: ...fully acquainted with operation instructions CAUTION The operation instructions constitute the main element of the purchase contract The user s failure to comply with these instructions is a default...

Page 2: ...ding or explosive substance e g gasoline nitro solvents petroleum etc food stuffs salt water Damage caused by pumping these types of liquids in not covered by the warranty Permitted temperature of the...

Page 3: ...orehole with a protective strip may damage the cable insulation This may damage the pump or cause electric shock to the operator Since the motor needs cooling during operation the diameter of the bore...

Page 4: ...bands At a great depth where the pump is installed the cable which is not mounted to the delivery pipe may break reason high weight of cable I It is recommended to lift the pump additionally at a stee...

Page 5: ...caused to people or objects resulting to feeding the pump without proper switch Pumps 4SDM MSC reason short length of cable are supplied with separate control box equipped with capacitor overload pro...

Page 6: ...surface on entire length The pump s support in one or several points may bend the pump and cause damage EQUIPMENT DISPOSAL The used product must be disposed as waste exclusively in selective waste co...

Page 7: ...two veins of the feed cable on the feeding strip only for three phase motors Too high resistance during the flow through the delivery pipe hose Check if the permitted lifting height for this specific...

Reviews: