Symptom: 

Possible cause: 

Solution to the problem: 

The security device against dry run has 
been engaged 

Wait until the quantity of water in the well 
is sufficient so the pump is switched on 
automatically. 

The security device against over-current 
has been engaged 

Wait until the motor cools down and 
switch on the pump. 
Check the cause of the overload. Remove 
the cause. 
Make sure the electric plug of the pump is 
properly inserted in electric socket. 
Check the corks at home and all installation 
switches which may cut off the power 
supply from the network 

The pump is not 
running 

No power supply 

Check if power supply is ensured near your 
house –  the power company may have cut 
off power in a larger area. 

A break in one wire of the feed cable 

Check resistance between the cable wires 

The pump keeps 
switching on and 
off 

Incorrect voltage or drop during start-up   Check voltage 

The filter screen is blocked at suction 

Disconnect the pump from electrical supply.
Take the pump out of the well and clean 
the filter  

Incorrect direction of the motor revolution
(Valid only for 3 phase motor) 

Change the two veins of the feed 
cable on the feeding strip (only for 
three-phase motors) 

Too high resistance during the flow 
through the delivery pipe (hose). 

Check if the permitted lifting height for this 
specific type of pump is not exceeded. The 
lifting height to be generated by the pump 
depends on the level difference between 
water table in the well the water is pumped 
out and the level at which the water is 
pumped, the length of the delivery pipe 
(hose) and its diameter. If resistance is too 
high for this specific type of pump replace 
the pump with a different one, of greater 

Sand in the pump (dirty water) 

Remove sand from the pump. Clean the 
well. 

Supply voltage is too low 

Check the supply voltage 

The pump is 
running but is 
not feeding 
water or is 
feeding too little 
water 

Too little water in the well 

Check  the  pump’s  position.  The  pump’s 
fuel feed port should be at least 2 m from 
the lowest dynamic level of water table. 

Pressure vessel is too small 

Replace the vessel with a bigger one 

No airbag in the pressure vessel 

Check the air pressure in the vessel. 
Add if necessary.  If the situation repeats 
often check if the diaphragm in the vessel  
is not broken 

The difference between the switching 
on and switching off pressure at 
pressure switch is too small 

Adjust the switch 

Frequent switching on 
and off the pump 

Suspended non-return valve 

Take the pump out and replace the valve. 

Summary of Contents for 3ti

Page 1: ...fully acquainted with operation instructions CAUTION The operation instructions constitute the main element of the purchase contract The user s failure to comply with these instructions is a default...

Page 2: ...ding or explosive substance e g gasoline nitro solvents petroleum etc food stuffs salt water Damage caused by pumping these types of liquids in not covered by the warranty Permitted temperature of the...

Page 3: ...orehole with a protective strip may damage the cable insulation This may damage the pump or cause electric shock to the operator Since the motor needs cooling during operation the diameter of the bore...

Page 4: ...bands At a great depth where the pump is installed the cable which is not mounted to the delivery pipe may break reason high weight of cable I It is recommended to lift the pump additionally at a stee...

Page 5: ...caused to people or objects resulting to feeding the pump without proper switch Pumps 4SDM MSC reason short length of cable are supplied with separate control box equipped with capacitor overload pro...

Page 6: ...surface on entire length The pump s support in one or several points may bend the pump and cause damage EQUIPMENT DISPOSAL The used product must be disposed as waste exclusively in selective waste co...

Page 7: ...two veins of the feed cable on the feeding strip only for three phase motors Too high resistance during the flow through the delivery pipe hose Check if the permitted lifting height for this specific...

Reviews: